VA-LCP 02.117.801Recalls & reported problems
Synthes GmbH · 2.7MM/3.5MM VA-LCP LAT DISTAL HUMERUS PL 1H/RT/69MM-SHORT · Class 2 · Implant
All models of VA-LCP (256)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982037381), received between Oct 29, 2020 and Oct 29, 2020 — classified as 1 injury.
1 other recall cover devices cleared under the same FDA submission (K120070); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- No Code Available1
- Nonunion/Delayed-union Bone Fracture1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 29, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
UPDATED EVENT DESCRIPTION: IT WAS REPORTED ON (B)(6) 2020, THAT PATIENT UNDERWENT REVISION SURGERY DUE TO NONUNION AND 1 BROKEN 60MM LENGTH VA LOCKING SCREW. ONE (1) VARIABLE ANGLE (VA) LOCKING COMPRESSION PLATE (LCP) EXTENDED MEDIAL DISTAL HUMERUS PLATE, SEVEN (7) VA LOCKING SCREWS AND ONE (1) CORTEX SCREW AND ONE (1) VA LCP DISTAL HUMERUS PLATE WERE SUCCESSFULLY EXPLANTED. THERE WAS A FRAGMENT OF THE SHAFT AND THE SCREWHEAD BUT IT WAS REMOVED EASILY WITHOUT ADDED TIME. PATIENT OUTCOME WAS UNKNOWN. THIS COMPLAINT INVOLVES TEN (10) DEVICES.
Patient problems: No Code Available; Nonunion/Delayed-union Bone Fracture
MAUDE report 10755457 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K120070. One submission often covers many models, so check the product and lot details in each record.
- Z-0124-2016 · Sep 28, 2015 · TerminatedSynthes 2.7MM/3.5MM VA-LCP Medial Distal Humerus Plates 10H/RT/186mm- Sterile and Synthes 2.7MM/3.5MM VA-LCP Extended Medial Distal Humerus Plates 10H/RT/189mm-Sterile The Synthes
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page