VA-LCP 02.118.400Recalls & reported problems

Synthes GmbH · 2.7MM VA-LCP LATERAL DISTAL FIBULA PLATE/3 HOLES/RIGHT · Class 2 · Implant

All models of VA-LCP (256)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10886982038784), received between Feb 21, 2018 and Jul 28, 2025 — classified as 2 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Material Twisted/Bent” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Twisted/Bent2
  • Adverse Event Without Identified Device or Use Problem1
  • Device Operates Differently Than Expected1
  • Device-Device Incompatibility1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Code Available1
  • Reaction1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 28, 2025Material Twisted/Bent; Material Twisted/Bent

    IT WAS REPORTED THAT ON AN UNKNOWN DATE THERE WAS RUST ON THE TAMPS / GUIDE BLOCK. IT COULD NOT BE REMOVED. THE LOCKING HOLES ON THE PLATES WERE STRIPPED. THERE WERE NO PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22629990 ↗
  • MalfunctionDec 29, 2020Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent

    IT WAS REPORTED THAT ON (B)(6) 2020, DURING AN UNKNOWN PROCEDURE, THE VARIABLE ANGLE (VA) LOCKING SCREWS DID NOT LOCK INTO THE PLATES USED. AN ALTERNATIVE PLATE WAS USED, AND THE SAME HOLE WAS STRIPPED. LOCKING COMPRESSION PLATE (LCP) DISTAL FIBULA PLATE WAS USED AND IT WORKED. THE DEPTH GAUGE TIP BROKE OFF DURING MEASUREMENT. THE LARGE FRAGMENT PLATE HAD RUST ON IT AS WELL. THE BROKEN FRAGMENTS WERE RETAINED IN THE PATIENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH A THREE (3) MINUTE SURGICAL DELAY. NO PATIENT CONSEQUENCES. CONCOMITANT DEVICES REPORTED: DEPTH GAUGE FOR 2.0MM AND 2.4MM SCREWS (PART NUMBER 319.006, LOT UNKNOWN, QUANTITY 1), 2.7MM VA-LCP LATERAL DISTAL FIBULA PLATE/5 HOLES/RIGHT (PART NUMBER 02.118.404, LOT UNKNOWN, QUANTITY 1), 4.5MM NARROW LCP® PLATE 11 HOLES/206MM (PART NUMBER 224.611, LOT UNKNOWN, QUANTITY 1). THIS REPORT INVOLVES ONE (1) 2.7MM VA-LCP LATERAL DISTAL FIBULA PLATE/3 HOLES/RIGHT. THIS IS REPORT 1 OF 3 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11087393 ↗
  • InjuryApr 11, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DEVICE REPORT REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT A PATIENT WAS IMPLANTED WITH A 2.7MM VA-LCP LATERAL DISTAL PLATE APPROXIMATELY ONE MONTH AGO, EXACT IMPLANT DATE IS UNKNOWN, AND IS PRESENTING FROM THE ANKLE TO THE FRONT PART OF THE FOOT WITH CONTACT DERMATITIS. THE SURGEON HAS REFERRED THE PATIENT TO THE DERMATOLOGY SPECIALIST, WHERE HE WAS DIAGNOSED AS HAVING CONTACT DERMATITIS. THE PATIENT IS REPORTED AS DOING WELL AFTER SEEING THE DERMATOLOGIST AND IS WALKING. THE IMPLANTS WILL NOT BE REMOVED AT THIS TIME AS THE PATIENT IS DOING WELL. THIS IS REPORT 1 OF 2 FOR (B)(4).

    Patient problems: Reaction

    MAUDE report 7422135 ↗
  • InjuryFeb 21, 2018Device Operates Differently Than Expected; Device Operates Differently Than Expected

    DEVICE REPORT FROM SYNTHES (B)(4) REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT DURING THE PLACEMENT OF A 2.7MM VARIABLE ANGLE LOCKING COMPRESSION PLATE FOR THE DISTAL FIBULA, ON (B)(6) 2018, THE SURGEON REPORTEDLY AFFIXED THE FIRST TWO 3.5 CORTICAL SCREWS TO THE 3-HOLE PLATE WITHOUT ISSUE; THE SECOND SCREW BEING PLACED IN THE DISTAL PART OF THE PLATE. WHILE PLACING THE THIRD SCREW, IT WOULD NOT LOCK INTO THE DISTAL HOLE OF THE PLATE AS EXPECTED. THE SCREW SEEMED TO DANCE AROUND THE HOLE IN THE PLATE. THE SURGEON PROCEEDED TO ATTEMPT FIXATION OF THE THIRD SCREW IN ANOTHER DISTAL HOLE BUT THE SCREW FAILED TO LOCK IN THE PLATE AND STILL SEEMED TO DANCE AROUND WITHOUT BEING LOCKED IN TO THE PLATE AS EXPECTED. THE SURGEON TRIED SEVERAL TIMES TO PLACE THE SCREW WITHOUT ANY SUCCESS. THE SURGEON PROCEEDED TO REMOVE THE PLATE WITH SCREWS. IT WAS SUGGESTED BY THE SURGICAL TECHNICIAN THAT THE SURGEON USE THE SAME PLATE AND SCREWS WHILE USING A LONGER METAPHYSEAL SCREW IN THE MIDDLE OF THE PLATE (AS THE BONE MAY BE MORE POROUS AND WEAKER POSSIBLY DUE TO THE PATIENT¿S OSTEOPOROTIC BONE). IN THE END, THE SURGEON CHOSE TO PLACE A FIVE HOLE PLATE; PRE-DRILLING 2 ADDITIONAL HOLES FOR

    Patient problems: No Code Available

    MAUDE report 7286129 ↗

Other Screw, fixation, bone devices

All Screw, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page