NA 02.206.220Recalls & reported problems
Synthes GmbH · 3.5MM CRTX SCREW/LOW PROF HD SELF-TAPPING/STAR DRIVE/20MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982050984), received between Mar 17, 2022 and Mar 17, 2022 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Hypersensitivity/Allergic reaction1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 17, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON UNKNOWN DATE, A PATIENT HAD FULL BODY RASH WHICH BEGAN AFTER AN ANKLE FRACTURE REPAIR WITH ONE (1) 3.5 MM LCP ONE-THIRD TUBULAR PLATE AND EIGHT (8) 3.5 MM CORTEX SCREWS. ALLERGY TESTING HAS CONFIRMED THE PATIENT IS ALLERGIC TO INDIUM (III) CHLORIDE, A COMPOUND FOUND IN SOME METAL ALLOYS WHICH MAYBE OF THE IMPLANTS. NO FURTHER INFORMATION PROVIDED. THIS REPORT IS FOR ONE (1) 3.5MM CRTX SCREW/LOW PROF HD SELF-TAPPING/STAR DRIVE/20MM THIS IS REPORT 2 OF 9 FOR COMPLAINT PC-(B)(4).
Patient problems: Hypersensitivity/Allergic reaction
MAUDE report 13793146 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page