NA 02.206.228Recalls & reported problems
Synthes GmbH · 3.5MM CRTX SCREW/LOW PROF HD SELF-TAPPING/STAR DRIVE/28MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 6
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10886982051066), received between Jan 8, 2018 and Jan 28, 2022 — classified as 6 injuries.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Break3
- Material Fragmentation1
Patient problems
- Nonunion/Delayed-union Bone Fracture4
- Malunion of Bone3
- Impaired Healing2
- No Code Available2
- Failure of Implant1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryJan 28, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON (B)(6) 2021, PATIENT UNDERWENT A REMOVAL OF VARIABLE ANGLE MEDIAL TIBIA PLATE AND CORRESPONDING SCREWS DUE TO NONUNION. THE MEDIAL PLATE WAS ORIGINALLY PUT ON THE LATERAL SIDE OF THE PATIENTS TIBIA. SURGEON REMOVED ALL HARDWARE, CREATED AN OSTEOTOMY, THEN PUT IN A ZIMMER HINDFOOT NAIL AS WELL AS SYNTHES VA PROXIMAL TIBIA PLATE. PATIENT CONSEQUENCES WERE REPORTED. THIS REPORT IS FOR ONE (1) 3.5 CRTX SCR LOW PROF HD STPING/SD/28. THIS IS REPORT 7 OF 14 FOR COMPLAINT PC-(B)(4).
Patient problems: Malunion of Bone; Nonunion/Delayed-union Bone Fracture
MAUDE report 13387979 ↗InjuryJan 28, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON (B)(6) 2021, PATIENT UNDERWENT A REMOVAL OF VARIABLE ANGLE MEDIAL TIBIA PLATE AND CORRESPONDING SCREWS DUE TO NONUNION. THE MEDIAL PLATE WAS ORIGINALLY PUT ON THE LATERAL SIDE OF THE PATIENTS TIBIA. SURGEON REMOVED ALL HARDWARE, CREATED AN OSTEOTOMY, THEN PUT IN A ZIMMER HINDFOOT NAIL AS WELL AS SYNTHES VA PROXIMAL TIBIA PLATE. PATIENT CONSEQUENCES WERE REPORTED. THIS REPORT IS FOR ONE (1) 3.5 CRTX SCR LOW PROF HD STPING/SD/28. THIS IS REPORT 3 OF 14 FOR COMPLAINT (B)(4).
Patient problems: Malunion of Bone; Nonunion/Delayed-union Bone Fracture
MAUDE report 13387898 ↗InjuryJan 28, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON (B)(6) 2021, PATIENT UNDERWENT A REMOVAL OF VARIABLE ANGLE MEDIAL TIBIA PLATE AND CORRESPONDING SCREWS DUE TO NONUNION. THE MEDIAL PLATE WAS ORIGINALLY PUT ON THE LATERAL SIDE OF THE PATIENTS TIBIA. SURGEON REMOVED ALL HARDWARE, CREATED AN OSTEOTOMY, THEN PUT IN A ZIMMER HINDFOOT NAIL AS WELL AS SYNTHES VA PROXIMAL TIBIA PLATE. PATIENT CONSEQUENCES WERE REPORTED. THIS REPORT IS FOR (1) 2.7 VA LCKNG SCR SLF-TPNG T8 SD REC 36. THIS IS REPORT 10 OF 14 FOR COMPLAINT (B)(4).
Patient problems: Malunion of Bone; Nonunion/Delayed-union Bone Fracture
MAUDE report 13387794 ↗InjuryJul 15, 2019Break; Break
CONCOMITANT DEVICES REPORTED: 2.7MM VARIABLE ANGLE LOCKING SCREWS (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY# 4), 3.5 CORTEX SCREWS (PART# 02.206.226, LOT# 7624795, QUANTITY# 1), 2.7MM CORTEX SCREWS (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY# 5) 2.7/3.5MM VA-LCP ANTEROLATERAL DISTAL TIBIA PL/10 HOLES/RIGHT (PART# 02.118.208, LOT# 7571300, QUANTITY# 1). THIS IS REPORT 6 OF 7 FOR (B)(4).
Patient problems: Impaired Healing; No Code Available
MAUDE report 8789781 ↗InjuryJul 15, 2019Break; Break
IT WAS REPORTED THAT ON (B)(6) 2019, THE PATIENT UNDERWENT REVISION SURGERY OF A VARIABLE ANGLE LOCKING COMPRESSION PLATE (VA-LCP) ANTEROLATERAL DISTAL TIBIAL PLATE 10 HOLES RIGHT DUE TO NONUNION. THERE WERE SIX (6) 2.7 MM VARIABLE ANGLE LOCKING SCREWS REMOVED, OUT OF SIX (6) SCREWS TWO (2) WERE BROKEN. ALSO HAD FOUR (4) 3.5 CORTEX SCREWS THAT WERE REMOVED AS WELL, THREE (3) OUT OF 4 SCREWS WERE BROKEN. THE 2.7 MM LOCKING COMPRESSION PLATE 7 HOLES PLATE WAS REMOVED, WITH THAT PLATE THERE WERE (6) 2.7MM CORTEX SCREWS ONE (1) WAS BROKEN. THE SURGEON REPLACE THE TIBIAL WITH ANOTHER VARIABLE ANGLE (VA) ANTEROLATERAL DISTAL TIBIA PLATE. IT WAS A 14-HOLE RIGHT. ENDED UP WITH A (4) CORTEX SCREWS IN THE SHAFT AND 5 (VA) LOCKING SCREW DISTALLY. THERE WAS ONE FRAGMENT THAT IS NON-RETRIEVABLE IT WAS THE SCREWS WERE INCASED IN BONE, IT WAS NOT REMOVED TO AVOID EXTENSIVE DISSECTION. IT WAS LEFT IN THE PATIENT AND NO PLAN TO REMOVE. THE ORIGINAL DATE OF IMPLANT WAS ON (B)(6) 2018. OTHER THAN THE TIMES IT TAKES TO REMOVE THE HARDWARE THERE WERE NO OTHER SURGICAL DELAYS. ALL OTHER HARDWARE WAS REMOVED COMPLETELY AND SUCCESSFULLY. PROCEDURE OUTCOME WAS GOOD. PATIENT WAS IN STABLE CONDITION AND TOL
Patient problems: Impaired Healing; No Code Available
MAUDE report 8789255 ↗InjuryJan 8, 2018Break; Material Fragmentation; Break; Material Fragmentation
IT WAS REPORTED THAT A PATIENT HAD TO UNDERGO REVISION SURGERY ON (B)(6) 2017 FOR REMOVAL OF 2.7/3.5MM VARIABLE ANGLE-LOCKING COMPRESSION (VA-LCP) MEDIAL DISTAL TIBIA PLATE/8 HOLES/LEFT IMPLANTED ON (B)(6) 2017. THE HARDWARE REMOVAL WAS DUE SIX BROKEN SCREWS AND NON-UNION. THE HEADS OF THE TWO 3.5MM CORTEX SCREW 26MM, ONE 3.5MM CORTEX SCREW 28MM AND THREE UNKNOWN LOCKING SCREWS WERE REMOVED. THE SHAFT OF ALL THESE SCREWS WERE RETAINED IN THE PATIENT AND WERE NOT REMOVED. NOTHING WAS IMPLANTED DURING REVISION SURGERY AS THE SURGEON JUST WANTED TO RULE OUT THE INFECTION BY REMOVING THE BROKEN SCREWS. THE SURGERY WAS COMPLETED WITHOUT ANY SURGICAL DELAY AND THE PATIENT WAS STABLE AFTER THE SURGERY. CONCOMITANT DEVICES REPORTED: 2.7/3.5MM VA-LCP MEDIAL DISTAL TIBIA PLATE/8 HOLES/LEFT (PART # 02.118.007, LOT # UNKNOWN, QTY # 1). THIS REPORT IS FOR ONE (1) 3.5MM CORTEX SCREW 28MM. THIS IS REPORT 3 OF 4 FOR COMPLAINT (B)(4).
Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture
MAUDE report 7173534 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page