NA 02.211.201Recalls & reported problems
Synthes GmbH · 2.4/2.7MM VA-LOCKING X-PLATE EXTRA SMALL · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982053824), received between Apr 11, 2024 and Apr 11, 2024 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Pain1
- Unspecified Infection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 11, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IN COLLABORATION WITH DEPUY SYNTHES, DR. , TOGETHER WITH (B)(6) CLINIC FOUNDATION DATABASE DESIGNERS, PROGRAM MANAGERS, RESEARCH ASSISTANTS, AND BIOSTATISTICIANS, HAS DEVELOPED A REPORT THAT SUMMARIZES SAFETY AND EFFECTIVENESS DATA ON 100 PATIENTS WHO UNDERWENT FOOT SURGERY AT (B)(6) BETWEEN 2008 AND 2023 UTILIZING DEPUY SYNTHES (DPS) FOOT PLATES. SOME PATIENTS WERE NOTED TO HAVE ADJUNCTIVE DEPUY SYNTHES DEVICES USED OUTSIDE OF THE PLATES/SCREWS. PATIENT #25 70-YEAR-OLD MALE WAS IMPLANTED WITH A VA LCP FOREFOOT/MIDFOOT PLATES (02.211.201) WITH 4 SCREWS. ONE ADDITIONAL ADJUNCTIVE FIXATION SCREW WAS USED FOR FIXATION. POST OP COMPLICATION WAS REPORTED 1. PERSISTENT PAIN; 2. OSTEOMYELITIS OF CALCANEUS (POST-1ST REVISION SURGERY) THE COMPLICATION IS NOTED TO BE RELATED TO THE PROCEDURE OR IMPLANTS. THERE IS NO DEVICE FAILURE NOTED. TREATMENT: 1. REMOVAL HARDWARE FOOT (RIGHT), 1. 2 SCREWS FROM TALOCALCANEAL ARTHRODESIS 2. SECOND INCISION. 4 SCREWS AND 1 PLATE, IN ADDITION, ONE 6.5 MM SCREW FROM A THIRD INCISION FROM THE TALONAVICULAR ARTHRODESIS 3. APPLICATION OF HYDROCET BONE GRAFT ; 2. DEBRIDEMENT OF RIGHT CALCANEUS OSTEOMYELITIS, WHICH INCLUDED DEBRIDEMENT OF BONE, SKIN, SUBCUTANEOUS
Patient problems: Pain; Unspecified Infection
MAUDE report 19091003 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page