VA-LCP 02.211.255Recalls & reported problems

Synthes GmbH · 2.4/2.7MM VA-LCP T-FUSION PL 2 HOLE HEAD/LONG · Class 2 · Implant

All models of VA-LCP (256)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982054562), received between Apr 10, 2024 and Apr 11, 2024 — classified as 2 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 2 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Hematoma1
  • Pain1
  • Wound Dehiscence1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 11, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON AN UNKNOWN DATE THAT IN COLLABORATION WITH DEPUY SYNTHES, DR., TOGETHER WITH CLINIC (B)(6) DATABASE DESIGNERS, PROGRAM MANAGERS, RESEARCH ASSISTANTS, AND BIOSTATISTICIANS, HAS DEVELOPED A REPORT THAT SUMMARIZES SAFETY AND EFFECTIVENESS DATA ON 100 PATIENTS WHO UNDERWENT FOOT SURGERY AT (B)(6) BETWEEN 2008 AND 2023 UTILIZING DEPUY SYNTHES (DPS) FOOT PLATES. SOME PATIENTS WERE NOTED TO HAVE ADJUNCTIVE DEPUY SYNTHES DEVICES USED OUTSIDE OF THE PLATES/SCREWS. PATIENT #10 53-YEAR-OLD FEMALE WAS IMPLANTED WITH A VA LCP FOREFOOT/MIDFOOT PLATES (02.211.255) WITH 5 SCREWS. POST OP COMPLICATION WAS REPORTED FOR 1. SURGICAL WOUND DEHISCENCE, LEFT FOOT. 2. HEMATOMA, LEFT FOOT. THE COMPLICATION IS NOTED TO BE NOT RELATED TO THE PROCEDURE OR IMPLANTS. REHOSPITALIZATION WAS REQUIRED FOR 1. SURGICAL WOUND DEHISCENCE, LEFT FOOT. 2. HEMATOMA, LEFT FOOT. TREATMENT: 1. EVACUATION OF HEMATOMA, LEFT FOOT. 2. SECONDARY CLOSURE, SURGICAL WOUND, LEFT FOOT. 3. APPLICATION OF WOUND VAC, LEFT FOOT THIS REPORT IS FOR ONE (1) 2.4/2.7 VA-LCP T-FUSN PL 2 HOLE HD/LONG THIS IS REPORT 1 OF 6 FOR COMPLAINT (B)(4).

    Patient problems: Hematoma; Wound Dehiscence

    MAUDE report 19089370 ↗
  • InjuryApr 10, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FOOT PLATES: IN COLLABORATION WITH DEPUY SYNTHES, TOGETHER WITH CLEVELAND CLINIC FOUNDATION (CCF) DATABASE DESIGNERS, PROGRAM MANAGERS, RESEARCH ASSISTANTS, AND BIOSTATISTICIANS, HAS DEVELOPED A REPORT THAT SUMMARIZES SAFETY AND EFFECTIVENESS DATA ON 100 PATIENTS WHO UNDERWENT FOOT SURGERY AT CCF BETWEEN 2008 AND 2023 UTILIZING DEPUY SYNTHES (DPS) FOOT PLATES. SOME PATIENTS WERE NOTED TO HAVE ADJUNCTIVE DEPUY SYNTHES DEVICES USED OUTSIDE OF THE PLATES/SCREWS. PATIENT #5 27-YEAR-OLD FEMALE WAS IMPLANTED WITH A VA LCP FOREFOOT/MIDFOOT PLATES (02.211.255) WITH 4 SCREWS. ONE ADDITIONAL ADJUNCTIVE FIXATION SCREWS WAS USED FOR FRACTURE FIXATION - INTERMETATARSAL JOINT. POST OP COMPLICATION WAS REPORTED FOR PAINFUL HARDWARE, RIGHT FOOT; BUT FRACTURE HEALED. THE COMPLICATION IS NOTED TO BE RELATED TO THE PROCEDURE OR IMPLANTS. THERE IS NO DEVICE FAILURE NOTED. TREATMENT: DEEP IMPLANT REMOVAL, RIGHT FOOT. THIS REPORT IS FOR A 2.4/2.7MM VA-LCP T-FUSION PL 2 HOLE HEAD/LONG. THIS IS REPORT 1 OF 5 FOR (B)(4).

    Patient problems: Pain

    MAUDE report 19083416 ↗

Other Screw, fixation, bone devices

All Screw, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page