MULTILOC 03.019.003Recalls & reported problems

Synthes GmbH · 10.0MM HOLLOW DRILL BIT FOR MULTILOC HUMERAL NAILING SYS · Class 1

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982069382), received between Dec 3, 2025 and Dec 3, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Contamination /Decontamination Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Contamination /Decontamination Problem1
  • Device-Device Incompatibility1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 3, 2025Contamination /Decontamination Problem; Device-Device Incompatibility; Contamination /Decontamination Problem; Device-Device Incompatibility

    IT WAS REPORTED THAT ON (B)(6) 2025, THE PATIENT UNDERWENT AN ORIF FOR PROXIMAL HUMERUS FRACTURE WITH THE REAMER. WHEN THE SURGEON TRIED TO USE THE REAMER OVER A GUIDE WIRE WITH A STOPPER, THE GUIDE WIRE WOULD NOT PASS THROUGH THE HOLLOW PART OF THE REAMER. WHEN THE SURGEON TRIED TO REMOVE THE GUIDE WIRE FROM THE PATIENT'S BODY AND PASS IT THROUGH THE REAMER, THE GUIDE WIRE AGAIN APPEARED TO BE CLOGGED AND WOULD NOT PASS THROUGH THE HOLLOW PART OF THE REAMER. AS A RESULT, THE USE OF THE AFFECTED PRODUCT WAS ABANDONED AND THE SURGERY WAS PERFORMED USING CROWN REAMER 11.5MM (03.019.004). THE SURGERY WAS COMPLETED SUCCESSFULLY WITHIN 30MINS OF DELAY. THE NURSE AND SURGEON AT THE SCENE OF THE INCIDENT COMMENTED THAT IT WAS LIKELY THAT A FOREIGN OBJECT HAD ALREADY BEEN LODGED IN THE HOLLOW PART AT THE TIME OF SHIPMENT. THE HOSPITAL APPARENTLY STERILIZES INSTRUMENTS WITHOUT CLEANING THEM AFTER DELIVERY. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23703956 ↗