NA 04.005.420Recalls & reported problems

Synthes GmbH · 4.0MM TI LOCKING SCREW W/T25 STARDRIVE 30MM FOR IM NAILS · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10886982085320), received between Jun 5, 2019 and Jan 26, 2023 — classified as 5 injuries.

2 other recalls cover devices cleared under the same FDA submission (K000089, K103002); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem5

Patient problems

  • No Code Available2
  • Nonunion/Delayed-union Bone Fracture2
  • Pain2
  • Skin Inflammation/ Irritation2

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 26, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2023 DURING INTRA-OP PATIENT REQUESTED TO HAVE BIL EX TIBIA NAILS, AND SCREWS, REMOVED DUE TO PAIN AND IRRITATION. THE IMPLANTS ON THE RIGHT SIDE WERE REMOVED WITHOUT INCIDENT. THE IMPLANTS ON THE LEFT WERE DIFFICULT. THE END CAP WAS REMOVED, AND NAIL EXTRACTOR THREADED INTO NAIL. THE DISTAL SCREW WAS REMOVED. WHILE ATTEMPTING TO REMOVE PROXIMAL SCREW, THE SCREW HEAD BROKE OFF OF THE SHAFT, AND LOOKED TO BE COLD WELDED INTO THE HEAD OF THE SCREW. THE BROKEN SCREW REMOVAL SET WAS OPENED AND SURGEON ATTEMPTED TO GET SCREW SHAFT OUT OF NAIL/TIBIA. THE BROKEN SCREW REMOVAL INSTRUMENTS WERE UNABLE TO ASSIST IN REMOVING THE SCREW SHAFT. THE SURGEON HAD TO OPEN SKIN MEDIALLY, AND USE AN OSTEOTOME TO CUT BONE AWAY FROM SCREW ON LATERAL AND MEDIAL SIDES. HE WAS THEN ABLE TO TAMP THE SCREW SHAFT OUT OF PATIENT. HE THEN PROCEEDED TO REMOVE THE NAIL. THERE WAS SURGICAL DELAY OF SIXTY (60) MINUTES. ACTION WAS TAKEN OF OPENED ADDITIONAL SETS/INSTRUMENTS, X-RAY WERE TAKEN AND THERE WERE FRAGMENTS GENERATED AND THE FRAGMENTS WERE REMOVED EASILY WITHOUT ANY ADDITIONAL INTERVENTION. SURGERY WAS COMPLETED SUCCESSFULLY. PATIENT CONSEQUENCES ARE UNKNOWN. THIS COMPLAINT IN

    Patient problems: Pain; Skin Inflammation/ Irritation

    MAUDE report 16247472 ↗
  • InjuryJan 26, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2023 DURING INTRA-OP PATIENT REQUESTED TO HAVE BIL EX TIBIA NAILS, AND SCREWS, REMOVED DUE TO PAIN AND IRRITATION. THE IMPLANTS ON THE RIGHT SIDE WERE REMOVED WITHOUT INCIDENT. THE IMPLANTS ON THE LEFT WERE DIFFICULT. THE END CAP WAS REMOVED, AND NAIL EXTRACTOR THREADED INTO NAIL. THE DISTAL SCREW WAS REMOVED. WHILE ATTEMPTING TO REMOVE PROXIMAL SCREW, THE SCREW HEAD BROKE OFF OF THE SHAFT, AND LOOKED TO BE COLD WELDED INTO THE HEAD OF THE SCREW. THE BROKEN SCREW REMOVAL SET WAS OPENED AND SURGEON ATTEMPTED TO GET SCREW SHAFT OUT OF NAIL/TIBIA. THE BROKEN SCREW REMOVAL INSTRUMENTS WERE UNABLE TO ASSIST IN REMOVING THE SCREW SHAFT. THE SURGEON HAD TO OPEN SKIN MEDIALLY, AND USE AN OSTEOTOME TO CUT BONE AWAY FROM SCREW ON LATERAL AND MEDIAL SIDES. HE WAS THEN ABLE TO TAMP THE SCREW SHAFT OUT OF PATIENT. HE THEN PROCEEDED TO REMOVE THE NAIL. THERE WAS SURGICAL DELAY OF SIXTY (60) MINUTES. ACTION WAS TAKEN OF OPENED ADDITIONAL SETS/INSTRUMENTS, X-RAY WERE TAKEN AND THERE WERE FRAGMENTS GENERATED AND THE FRAGMENTS WERE REMOVED EASILY WITHOUT ANY ADDITIONAL INTERVENTION. SURGERY WAS COMPLETED SUCCESSFULLY. PATIENT CONSEQUENCES ARE UNKNOWN. THIS COMPLAINT I

    Patient problems: Pain; Skin Inflammation/ Irritation

    MAUDE report 16247292 ↗
  • InjuryNov 10, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2020, THE PATIENT UNDERWENT A REVISION PROCEDURE AND REMOVAL OF THE MULTI LOCK FEMORAL NAIL. THE IMPLANT REMOVAL WAS DUE TO THE QUALITY OF IMPLANTS AND NON-UNION. INITIALLY, PATIENT HAD A ZIMMER BIOMET PROXIMAL HUMERUS PLATE THAT WAS REVISED TO SYNTHES MULTILOC HUMERAL NAIL DUE TO ZIMMER PLATE FAILURE. IT WAS ALSO MENTIONED THAT THE PATIENT HAD AN INFECTION PRIOR TO SURGICAL IMPLANT THAT ULTIMATELY LED TO THE NON-UNION. DURING THE PROCEDURE, THE FEMORAL IMPLANT WAS REMOVED AHEAD PROXIMAL NAIL TO GET THE PROXIMAL SCREW STILL INTACT. THE PATIENT WAS THEN REVISED TO A REVERSE SHOULDER. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. PATIENT STATUS IS UNKNOWN. THIS REPORT IS FOR ONE (1) 4.0MM TI LOCKING SCREW W/T25 STARDRIVE 30MM FOR IM NAILS. THIS IS REPORT 4 OF 8 FOR (B)(4).

    Patient problems: No Code Available; Nonunion/Delayed-union Bone Fracture

    MAUDE report 10816753 ↗
  • InjurySep 16, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED ON (B)(6) 2019, DURING AN UNKNOWN PROCEDURE, IT WAS FOUND OUT THAT AN UNKNOWN HUMERAL NAIL SET DO NOT HAVE AN UNKNOWN CADDY WITH AN UNKNOWN BLADES, UNKNOWN 4.0 TITANIUM SCREWS AND UNKNOWN END CAPS. ORIGINALLY, THE SALES CONSULTANT GETS THE SET AND THERE¿S GOING TO BE A TOTE WITH IMPLANTS FOR BLADES AND SCREWS AND END CAPS. THE SALES CONSULTANT CALLED THE FSL AND EVENTUALLY DISCOVERED THAT THERE WAS SUPPOSED TO BE A CADDY INSIDE THE SET. THE SALES CONSULTANT THEN GO AND DRIVE TO ANOTHER HOSPITAL AND RETURN WITH A TOTE FOR SAID IMPLANTS. THE PROCEDURE WAS SUCCESSFULLY COMPLETED; HOWEVER, THE PATIENT SPENT AN EXTRA 100 MINUTES UNDER ANESTHESIA. ALSO, THE END CAP AVAILABLE FROM THE OTHER HOSPITAL WAS NOT THE CORRECT SIZE, SO IT PROTRUDED FROM THE PATIENT¿S HUMERAL HEAD. RE-OPERATION IS MOST LIKELY. PROCEDURE AND PATIENT OUTCOME WERE UNKNOWN. THIS COMPLAINT INVOLVES THIRTY-EIGHT (38) DEVICES. THIS IS REPORT 7 FOR 10. (B)(4).

    Patient problems: No Code Available

    MAUDE report 9072663 ↗
  • InjuryJun 5, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2019, PATIENT UNDERWENT REMOVAL OF TITANIUM CANNULATED HUMERAL NAIL EX, TITANIUM LOCKING SCREW 30MM AND TITANIUM LOCKING SCREW 38MM. IMPLANTS WERE REMOVED DUE TO HUMERAL SHAFT NON-UNION. THE PATIENT ORIGINALLY HAD THE HUMERAL NAIL CONSTRUCT IMPLANTED TO TREAT HIS HUMERUS FRACTURE ON AN UNKNOWN DATE. PATIENT WAS REVISED TO A 9 HOLE 4.5MM LCP BROAD PLATE AND EIGHT (8) 4.5MM CORTEX SCREWS. THE SURGERY WAS SUCCESSFULLY COMPLETED WITHOUT DELAY. THIS IS REPORT 2 OF 3 FOR (B)(4).

    Patient problems: Nonunion/Delayed-union Bone Fracture

    MAUDE report 8671515 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K000089, K103002. One submission often covers many models, so check the product and lot details in each record.

  • Z-2059-2012 · May 22, 2012 · Terminated
    4.5mm TI Multiloc Screw Length 38MM-Sterile Expiration: 04/29/2012 REF 04.019.038S Manufactured or Distributed by Synthes (USA) 1101 Synthes Avenue, Monument CO 80132 4.5MM TI Mu
  • Z-2060-2012 · May 22, 2012 · Terminated
    4.5mm TI Multiloc Screw Length 28MM-Sterile Expiration: 04/29/2012 REF 04.019.028S Manufactured or Distributed by Synthes (USA) 1101 Synthes Avenue, Monument CO 80132 4.5MM TI Mu

Other Screw, fixation, bone devices

All Screw, fixation, bone devices →