NA 04.005.422SRecalls & reported problems
Synthes GmbH · 4.0MM TI LOCKING SCREW W/T25 STARDRIVE 32MM F/IM NAILS-STER · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982085351), received between Feb 15, 2023 and Feb 15, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K000089, K103002); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 15, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE PATIENT UNDERWENT ORIF FOR PROXIMAL HUMERUS FRACTURE WITH THE PRODUCTS IN QUESTION. AFTER OPENING THE NAIL, THE SURGEON PERFORMS A DRY CHECK ON THE INSTRUMENT TABLE AND CONFIRMS THAT THE DRILL HAS PASSED THROUGH BEFORE INSERTING THE NAIL INTO THE BODY. HE THEN INSERTED THE GUIDEWIRE FOR BLADE INSERTION AS PER THE PROCEDURE MANUAL, MEASURED AND INSERTED. ONCE IT INTERFERED WITH THE NAIL, IT WAS PULLED BACK AND REINSERTED. AS THE BLADE ADVANCED ALONG THE GUIDEWIRE, THE SCREWS IN QUESTION WERE INSERTED DISTALLY OVER THE DEVICE. WHEN ATTEMPTING TO REMOVE THE DEVICE FOR END CAP INSERTION AFTER DISTAL SCREW INSERTION, IT WAS DISCOVERED THAT THE BLADE AND DISTAL LATERAL STOP SCREWS WERE NOT IN THE NAIL. HE THEN REMOVED THE BLADE AND SCREWS FROM THE BODY AND REINSERTED THE NAIL. THIS TIME HE INSERTED FROM THE DISTAL LATERAL STOP SCREWS AND THE PROXIMAL BLADE, SO THEY WERE INSERTED WITH NO PROBLEM. THE BLADES WERE THE SAME LENGTH, BUT THE DISTAL SCREWS CHANGED LENGTH. THE SCREWS IN QUESTION ARE SCREWS THAT COULD NOT BE INSERTED THROUGH THE DEVICE. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHIN 30 M
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16378957 ↗MalfunctionFeb 15, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE PATIENT UNDERWENT ORIF FOR PROXIMAL HUMERUS FRACTURE WITH THE PRODUCTS IN QUESTION. AFTER OPENING THE NAIL, THE SURGEON PERFORMS A DRY CHECK ON THE INSTRUMENT TABLE AND CONFIRMS THAT THE DRILL HAS PASSED THROUGH BEFORE INSERTING THE NAIL INTO THE BODY. HE THEN INSERTED THE GUIDEWIRE FOR BLADE INSERTION AS PER THE PROCEDURE MANUAL, MEASURED AND INSERTED. ONCE IT INTERFERED WITH THE NAIL, IT WAS PULLED BACK AND REINSERTED. AS THE BLADE ADVANCED ALONG THE GUIDEWIRE, THE SCREWS IN QUESTION WERE INSERTED DISTALLY OVER THE DEVICE. WHEN ATTEMPTING TO REMOVE THE DEVICE FOR END CAP INSERTION AFTER DISTAL SCREW INSERTION, IT WAS DISCOVERED THAT THE BLADE AND DISTAL LATERAL STOP SCREWS WERE NOT IN THE NAIL. HE THEN REMOVED THE BLADE AND SCREWS FROM THE BODY AND REINSERTED THE NAIL. THIS TIME HE INSERTED FROM THE DISTAL LATERAL STOP SCREWS AND THE PROXIMAL BLADE, SO THEY WERE INSERTED WITH NO PROBLEM. THE BLADES WERE THE SAME LENGTH, BUT THE DISTAL SCREWS CHANGED LENGTH. THE SCREWS IN QUESTION ARE SCREWS THAT COULD NOT BE INSERTED THROUGH THE DEVICE. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHIN 30 M
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16378953 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K000089, K103002. One submission often covers many models, so check the product and lot details in each record.
- Z-2059-2012 · May 22, 2012 · Terminated4.5mm TI Multiloc Screw Length 38MM-Sterile Expiration: 04/29/2012 REF 04.019.038S Manufactured or Distributed by Synthes (USA) 1101 Synthes Avenue, Monument CO 80132 4.5MM TI Mu
- Z-2060-2012 · May 22, 2012 · Terminated4.5mm TI Multiloc Screw Length 28MM-Sterile Expiration: 04/29/2012 REF 04.019.028S Manufactured or Distributed by Synthes (USA) 1101 Synthes Avenue, Monument CO 80132 4.5MM TI Mu
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page