VA-LCP 04.111.680SRecalls & reported problems
Synthes GmbH · 2.4/2.7 TI VA-LCP 2-C DRP STD 6H HD/10H SHAFT/145MM/RT-STER · Class 2 · Implant
All models of VA-LCP (256)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982101990), received between Jan 26, 2023 and Feb 14, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 14, 2023Use of Device Problem; Use of Device Problem
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE PATIENT UNDERWENT OPEN REDUCTION INTERNAL FIXATION (ORIF) FOR FRACTURE OF THE FOREARM. THE SURGEON ORDERED UP TO EXTRA-LONG ON THE RIGHT AND NORMAL SIZE ON THE LEFT. DURING THE SURGERY, AN INQUIRY WAS MADE FROM THE OPERATING ROOM REGARDING THE EXTRA-LONG PLATE. THE PLATE DID NOT SHOW UP IN TIME BECAUSE THE PROCEDURE FOR THE RIGHT RADIUS HAD ALREADY BEEN COMPLETED AND THE LEFT RADIUS WAS ALREADY BEING PROCESSED. THE PREPARED RIGHT 10-HOLE PLATE WAS USED FOR THE LEFT RADIUS. SURGERY WAS COMPLETED SUCCESSFULLY WITH LESS THAN THIRTY MINUTES DELAY. THERE WAS NO PATIENT CONSEQUENCE. THIS REPORT IS FOR A 2.4/2.7 TI VA-LCP 2-C DRP STD 6H HD/10H SHAFT/145MM/RT-STER. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16375704 ↗MalfunctionJan 26, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN HONG KONG AS FOLLOWS: IT WAS REPORTED THAT ON JANUARY 3, 2023, THE VA DRILL SLEEVE COULD NOT ATTACH TO THE VA SCREW HOLES. THERE WERE NO PATIENT CONSEQUENCES. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT INVOLVES ONE 2.4/2.7 TI VA-LCP 2-C DRP STD 6H HD/10H SHAFT/145MM/RT-STER. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16245474 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page