VA-LCP 04.117.901SRecalls & reported problems
Synthes GmbH · 2.7MM/3.5MM TI VA-LCP LAT DSTL HUM PL 1H/LT/69MM SHRT-STER · Class 2 · Implant
All models of VA-LCP (256)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982107077), received between Jul 28, 2023 and Jul 28, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
1 other recall cover devices cleared under the same FDA submission (K120070); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 28, 2023Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6)2023, THE PATIENT UNDERWENT AN ORIF SURGERY FOR DISTAL HUMERUS FRACTURE. THE AFFECTED AREA WAS FIXED IN THE ORDER OF THE MEDIAL PLATE, THEN THE LATERAL PLATE. INITIALLY, THE SCREW WAS INSERTED AT A FIXED ANGLE, BUT WHEN IT WAS CHECKED WITH AN IMAGE INTENSIFIER, IT WAS FOUND THAT THE TIP OF THE SCREW PENETRATED FORWARD. THE SCREW WAS REMOVED AND REINSERTED SEVERAL TIMES, BUT THE ANGLE DID NOT CHANGE SO THE SURGEON REDRILLED WITH A VARIABLE ANGLE AND INSERTED THE SCREW. NEAR THE END OF THE LATERAL PLATE FIXATION, THE SURGEON SAID THAT THE 2ND SCREW FROM THE DISTAL SIDE COULD NOT BE LOCKED AND WAS COMING OUT. THE SCREW CAME OUT, SO NO SCREW WAS INSERTED IN THAT SCREW HOLE. ONLY ONE SCREW COULD BE INSERTED DISTALLY, SO AN ADDITIONAL SCREW WAS INSERTED FROM THE DISTAL LATERAL DIRECTION TO THE PROXIMAL LATERAL. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A 2.7MM/3.5MM TI VA-LCP LAT DSTL HUM PL 1H/LT/69MM SHRT-STER. THIS IS REPORT 1 OF 3 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17415920 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K120070. One submission often covers many models, so check the product and lot details in each record.
- Z-0124-2016 · Sep 28, 2015 · TerminatedSynthes 2.7MM/3.5MM VA-LCP Medial Distal Humerus Plates 10H/RT/186mm- Sterile and Synthes 2.7MM/3.5MM VA-LCP Extended Medial Distal Humerus Plates 10H/RT/189mm-Sterile The Synthes
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page