Skip to content

NA 04.130.212Recalls & reported problems

Synthes GmbH · 1.5MM TI VA-LCKNG SCR SLF-TPNG WITH T4 STARDRIVE RECESS 12MM · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982112774), received between Sep 26, 2023 and Sep 26, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 26, 2023Break; Break

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE PATIENT UNDERWENT ORIF SURGERY FOR THIRD AND FOURTH METACARPAL FRACTURE WITH SCREWDRIVER SHAFT, DRILL BIT, VA LOCKING STRAIGHT PLATE AND LOCKING SCREWS. WHILE THE SURGEON WAS DRILLING TO FIX THE VA LOCKING STRAIGHT PLATE, THE DRILL BIT BROKE. FORTUNATELY, THE DRILL BIT COULD BE REMOVED FROM THE BODY, AND THE SURGERY PROCEEDED. NEXT, THE SCREWDRIVER SHAFT BROKE WHEN INSERTING THE LOCKING SCREW. BUT THIS ONE WAS ALSO REMOVED FROM THE BODY. THE SURGEON PROCEEDED WITH THE SURGERY USING A SCREWDRIVER OF THE SAME STANDARD. AFTER THAT, WHEN INSERTING ANOTHER LOCKING SCREW, TWO SCREW HEADS BROKE. THE SURGEON REMOVED ONE LOCKING SCREW, BUT THE OTHER LOCKING SCREW WAS INSERTED IN A GOOD POSITION FOR FIXATION, SO THE SURGEON LEFT IT IN PLACE AND REMOVED THE IMPLANT. THE SURGEON THEN CHANGED TO 2.0MM PLATE AND SCREW AND FIXED IT, COMPLETING THE SURGERY. ALL THAT REMAINS IN THE PATIENT¿S BODY IS A SINGLE SCREW WITH A BROKEN SCREW HEAD. THE SURGEON THOUGHT THE CAUSE OF THE FRACTURE WAS THAT THE PATIENT WAS 19 YEARS OLD AND HAD GOOD BONE QUALITY. THE SURGERY WAS COMPLETED SUCCESSFULLY MORE TH

    Patient problems: Insufficient Information

    MAUDE report 17819879 ↗