LCP 224.581Recalls & reported problems
Synthes GmbH · 4.5MM NARROW LCP® PLATE 8 HOLES/152MM · Class 2 · Implant
All models of LCP (367)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982158505), received between Feb 21, 2018 and Feb 21, 2018 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Nonunion/Delayed-union Bone Fracture1
- Unspecified Infection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 21, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT HAD ORIGINAL SURGERY PERFORMED ON (B)(6) 2014. PATIENT WAS REVISED ON (B)(6) 2015 DUE TO NON-UNION. THE PATIENT WAS REVISED AGAIN ON (B)(6) 2018 DUE TO NONUNION OF HUMERUS AND ONE BROKEN 4.0 MM LOCKING SCREW. DURING REVISION SURGERY THE HEAD OF THE BROKEN SCREW WAS REMOVED AND THE SHAFT OF THE SCREW WAS LEFT INSIDE THE PATIENT. ALSO, ONE (1) 4.5 MM NARROW LCP PLATE 8 HOLES/152 MM, THREE (3) 4.5 MM CORTEX SCREWS, THREE (3) 3.5 MM CORTEX SCREWS, ONE (1) 3.5 MM LCP PLATE 6 HOLES 85 MM, TWO (2) 3.5 MM LOCKING SCREWS AND TWO (2) 4.0 MM LOCKING SCREWS WERE REMOVED INTACT. THE FRACTURE ENDS WERE SHORTENED AND THE PATIENT WAS REPLATED WITH A 7 HOLE 4.5 MM BROAD PLATE (VIVIGEN BONE GRAFT). THE REVISION SURGERY WAS SUCCESSFULLY COMPLETED WITHOUT ANY DELAY AND WITHOUT ANY OTHER MEDICAL INTERVENTION REQUIRED. PATIENT WAS REPORTED TO BE OKAY AFTER THE SURGERY. LATER, IT WAS INFORMED BY THE HOSPITAL THAT THE INTRA-OP CULTURES CAME BACK POSITIVE FROM THE DAY OF SURGERY. THE DOCTOR HAS DECIDED TO USE ANTIBIOTICS FOR TREATMENT OF THE INFECTION. THIS REPORT ADDRESSES SECOND REVISION SURGERY DUE TO BROKEN SCREW AND INFECTION. THE FIRST REVISION SURGERY DUE TO NON-UNION
Patient problems: Nonunion/Delayed-union Bone Fracture; Unspecified Infection
MAUDE report 7287475 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page