LCP 224.661Recalls & reported problems
Synthes GmbH · 4.5MM NARROW LCP® PLATE 16 HOLES/296MM · Class 2 · Implant
All models of LCP (367)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982158628), received between Oct 23, 2017 and Oct 23, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Failure of Implant1
- Nonunion/Delayed-union Bone Fracture1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 23, 2017Break; Break
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED ON (B)(6) 2017 DUE TO BROKEN PLATE AND TO TREAT TIBIA FRACTURE. INITIALLY THE PATIENT WAS IMPLANTED WITH ONE (1) PLATE AND 12 (TWELVE) SCREWS. THE PLATE BROKE INTERNALLY AND PATIENT PRESENTED WITH PAIN. THE FRACTURE DID NOT HEAL AS EXPECTED (NON-UNION). DUE TO THIS REASON, REVISION SURGERY WAS PERFORMED. ALL IMPLANTS (1 PLATE AND 12 SCREWS) REMOVED WITHOUT ANY DIFFICULTY. POST-OPERATIVE X-RAYS CONFIRMED NO FRAGMENTS WERE RETAINED. REVISION SURGERY WAS COMPLETED SUCCESSFULLY WITHOUT ANY DELAY. THE PATIENT WAS REVISED TO NEW SYNTHES PLATE AND ALSO COMPETITOR¿S DEVICE (RESTORATION HIP, STRYKER). PATIENT IS NOW REPORTED TO BE IN STABLE CONDITION. CONCOMITANT DEVICES REPORTED: CORTEX SCREW (PART #: 214.836, QTY: 2), CORTEX SCREWS (PART #: 214.850, QTY: 2), CORTEX SCREWS (PART #: 214.838, QTY: 6), CORTEX SCREW (PART #: 214.840, QTY: 1), CORTEX SCREW (PART #: 214.834, QTY: 1) THIS REPORT IS FOR ONE(1) 4.5 MM NARROW LCP PLATE. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture; Pain
MAUDE report 6969799 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.