LCP 238.705Recalls & reported problems
Synthes (U.S.A.) LP · 3.5MM LCP® MEDIAL DISTAL TIBIA PLATE W/O TAB 8 HOLES-LEFT · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982162137), received between Oct 2, 2017 and Oct 2, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Failure of Implant1
- Nonunion/Delayed-union Bone Fracture1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 2, 2017Break; Break
IT WAS REPORTED THAT A PATIENT SUFFERED A GUNSHOT WOUND ON (B)(6) 2016 AND WAS EX-FIXED THE FOLLOWING DAY. THE PATIENT WAS IMPLANTED WITH AN EIGHT (8)-HOLE PLATE, FOUR (4) LOCKING SCREWS, AND 4 CORTICAL SCREWS ON (B)(6) 2016. ON AN UNKNOWN DATE, THE PATIENT COMPLAINED OF PAIN AND PRESENTED A BROKEN PLATE UPON A FOLLOW-UP X-RAY, CAUSING A NONUNION. IT IS UNKNOWN WHY THE PLATE BROKE. THE PATIENT WAS REVISED ON (B)(6) 2017. ALL SCREWS WERE REMOVED INTACT. THE PLATE WAS THE ONLY ONE REPORTED BROKEN. THE PATIENT RECEIVED A NEW PLATE (SAME TYPE - 3.5 MM LCP MEDIAL DISTAL TIBIA PLATE WITHOUT TAB, BUT LONGER IN LENGTH) IN THE TIBIA. THERE WAS A NONUNION AS WELL IN THE FIBULA, WHERE AN ORIGINAL LONG 3.5 MM SCREW DWELLED IN THE INTRAMEDULLARY CANAL. THE FIBULA WAS REVISED WITH A 3.5 MM LOCKING COMPRESSION PLATE (LCP). THE PATIENT WAS ALSO BONE GRAFTED WITH ILIAC BONE (AUTOGRAFT) AND CANCELLOUS CHIPS AT THE FRACTURE SITE OF THE TIBIA TO TRY TO OVERCOME THE NONUNION. THERE WAS NO SURGICAL TIME DELAY NOR PATIENT HARM REPORTED. NO ADDITIONAL INFORMATION IS AVAILABLE. THIS COMPLAINT INVOLVED 2 PARTS. CONCOMITANT DEVICES REPORTED: FOUR (4) 3.5 MM LOCKING SCREWS, (4) 3.5 MM CORTEX SCREWS. THIS REPO
Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture; Pain
MAUDE report 6909196 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page