LCP 239.991Recalls & reported problems
Synthes GmbH · 4.5MM LCP® MEDIAL PROXIMAL TIBIA PLATE 10H/LEFT 214MM · Class 2 · Implant
All models of LCP (367)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982163974), received between Jun 29, 2018 and Jun 29, 2018 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Unspecified Infection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 29, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE REPORT FROM SYNTHES EUROPE REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION DUE TO NON¿UNION AND INFECTION. ONE (1) VARIABLE ANGLE DISTAL PLATE, ELEVEN (11) VARIABLE ANGLE LOCKING SCREWS, TWO (2) 3.5 CORTEX SCREWS, ONE (1) LOCKING COMPRESSION PLATE PROXIMAL MEDIA TIBIA, ONE (1) T PLATE, SIX (6) LOCKING COMPRESSION PLATE SCREWS, AND FIVE (5) CORTEX SCREWS WERE REMOVED AND WERE REPLACED WITH A NEW VA DISTAL FEMUR PLATE AND A RETROGRADE/ANTEGRADE FEMORAL NAIL (RFNA). THE DATE OF THE ORIGINAL PROCEDURE IS UNKNOWN BUT WAS REPORTED MORE THAN SIX MONTHS BEFORE THE REPORTED ISSUES. IT WAS NOTED THE NON-UNION OCCURRED IN THE DISTAL FEMUR AND THE INFECTION DEVELOPED IN THE PROXIMAL TIBIA. ON AN UNKNOWN DATE, THE TIBIA WAS WASHED OUT AND DEBRIDED AND PLATES REMOVED. THE FEMUR WAS TO BE BONE GRAFTED; HOWEVER, IT WAS DISCOVERED A LARGE FRAGMENT OF BONE HAD DIED. THIS WAS REMOVED AND CEMENT SPACER WAS INSERTED. FEMORAL IMPLANTS REMAINED IN SITU. ON (B)(6) 2018, THE FEMORAL FIXATION WAS REVISED WITH VA DISTAL FEMUR PLATE AND RAFN NAIL AND BONE GRAFT. TIBIA IMPLANTS REMOVED, WASHED OUT AND SINUS EXCISED AS IT WAS STILL INFECTED. THERE WAS NO DELAY
Patient problems: Unspecified Infection
MAUDE report 7650986 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page