LCP 240.041Recalls & reported problems
Synthes GmbH · 4.5MM LCP PROXIMAL TIBIA PLATE 8 HOLES/154MM-LEFT · Class 2 · Implant
All models of LCP (367)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982164537), received between Aug 28, 2017 and Feb 9, 2018 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Nonunion/Delayed-union Bone Fracture2
- Inflammation1
- Unspecified Infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryFeb 9, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A PATIENT HAD A NON UNION OF A PROXIMAL THIRD TIBIA FRACTURE. THE ORIGINAL IMPLANT DATE WAS ABOUT 10 YEARS AGO. THE PLATE HAD THREE (3) 5.0MM LOCKING SCREWS AND THREE (3) CANNULATED 5.0MM LOCKING SCREWS. IMPLANTS WERE REMOVED WITHOUT ANY MAJOR ISSUE. THE PATIENT WAS PLACED WITH ANOTHER SYNTHES PLATE AND VIVIGEN BONE GRAFT. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO MEDICAL INTERVENTION NEEDED. NO SURGICAL DELAY WAS NOTED NO FRAGMENTS WERE REPORTED. THIS COMPLAINT INVOLVES TWO (2) DEVICE. THIS REPORT IS FOR ONE (1) PLATE. (B)(4).
Patient problems: Nonunion/Delayed-union Bone Fracture
MAUDE report 7259090 ↗InjuryAug 28, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT REMOVAL OF A TIBIA PLATE, FOUR CANNULATED LOCKING SCREWS, AND THREE CORTEX SCREWS DUE TO INFECTION, INFLAMMATION, AND NONUNION ON (B)(6) 2017. THE HARDWARE WAS ORIGINALLY IMPLANTED ON (B)(6) 2017 DURING AN OPEN REDUCTION INTERNAL FIXATION (ORIF) PROXIMAL LEFT TIBIAL PLATEAU FRACTURE. THE PATIENT FAILED TO FOLLOW POSTOPERATIVE DIRECTIONS WHICH INCLUDED REMOVING BANDAGE TOO EARLY POSTOPERATIVELY AND WALKING ON LEG BEFORE HE WAS DIRECTED TO. THE SURGEON STATED THAT THE INFECTION WAS DUE TO THE PATIENT'S NONCOMPLIANCE. THE SURGERY WAS SUCCESSFULLY COMPLETED WITH NO DELAY. THE PATIENT OUTCOME WAS REPORTED AS OKAY. THIS COMPLAINT IS (3) DEVICES 1 PLATE, UNK CORTEX SCREWS, UNK LOCKING SCREWS. THIS REPORT IS 1 OF 3 FOR (B)(4).
Patient problems: Inflammation; Nonunion/Delayed-union Bone Fracture; Unspecified Infection
MAUDE report 6825934 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page