DHS 338.28Recalls & reported problems
Synthes GmbH · DHS®/DCS® IMPACTOR · Class 1
All models of DHS (57)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 11
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 10886982193308), received between Jun 13, 2018 and Apr 2, 2025 — classified as 1 injury, 10 malfunctions.
The most frequently reported specific device problem is “Break” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Break7
- Appropriate Device Problem Term/Code Not Available3
- Crack1
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient4
- Insufficient Information2
- Hematoma1
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 2, 2025Break; Break
IT WAS REPORTED THAT ON (B)(6) 2025, DURING THE PROCEDURE, WHICH WAS A STANDARD DHS, UPON FOLLOWING THE STEPS PER THE SURGICAL TECHNIQUE, THE DHS/DCS IMPACTOR BROKE WHILE TRYING TO SEAT THE PLATE. SPECIFICALLY, THE TIP OF THE IMPACTOR BROKE. THERE WAS NO EXCESSIVE FORCE APPLIED TO THE IMPACTOR. THE BROKEN TIP WAS RECOVERED, HOWEVER THE IMPACTOR AND TIP AS A WHOLE WERE UNUSABLE. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO DELAYS, NEGATIVE OUTCOMES, OR INTERVENTION REQUIRED.
Patient problems: Insufficient Information
MAUDE report 21756454 ↗MalfunctionMar 22, 2024Break; Break
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN CANADA AS FOLLOWS: IT WAS REPORTED THAT DURING INSPECTION IN OF THE DHS SET, IT WAS DISCOVERED THAT THE DHS/DCS IMPACTOR WAS BROKEN. IT WAS DISCARDED. THERE WAS NO PATIENT CONSEQUENCE; THE ISSUE WAS DISCOVERED POSTOPERATIVELY. THIS REPORT INVOLVES ONE DHS®/DCS® IMPACTOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18959379 ↗MalfunctionOct 20, 2023Break; Break
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE PATIENT UNDERWENT ORIF SURGERY FOR FEMORAL TROCHANTERIC FRACTURE WITH DHS/DCS IMPACTOR. DURING SURGERY, THE DHS/DCS IMPACTOR IN QUESTION WAS USED TO INSERT THE TUBE PLATE BARREL PART INTO THE BODY, AND WHEN IT WAS STRUCK WITH A HAMMER, THE TIP OF THE DHS/DCS IMPACTOR BROKE AFTER BEING STRUCK SEVERAL TIMES. THE SURGERY WAS CONTINUED USING AN IN-HOSPITAL SUBSTITUTE AND WAS COMPLETED WITHOUT ANY PROBLEMS. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHOUT ANY SURGICAL DELAY. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A DHS®/DCS® IMPACTOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: Insufficient Information
MAUDE report 17974465 ↗MalfunctionFeb 22, 2022Crack; Device-Device Incompatibility; Crack; Device-Device Incompatibility
IT WAS REPORTED THAT ON UNKNOWN DATE, THE DHS IMPACTOR WAS UNABLE TO STERILIZE AND ASSEMBLE. CHIPPING AND CRACKING WERE NOTED. THIS MAY HAVE HAPPENED DURING CLEANING IN STERILE PROCESSING. THERE WAS NO PATIENT INVOLVEMENT. THIS COMPLAINT INVOLVES ONE (1) DEVICE DHS/DCS IMPACTOR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13580231 ↗InjuryJan 7, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT ON (B)(6) 2020, DURING A HIP SURGERY, A PIECE OF A BROKEN DYNAMIC HIP SYSTEM (DHS) SCREW WAS FOUND. THE SURGEON DID THE CASE TO WASH OUT A HIP THAT HAD A HEMATOMA. INITIALLY, THE PATIENT HAD A FACILITY DYNAMIC HIP SCREW PUT IN ON AN UNKNOWN DATE. WHEN THE SURGEON WASHED THE HIP OUT, A PIECE OF SOMETHING CAME OUT. IT APPEARS A SMALL PIECE OF THE IMPACTOR FOR THE DYNAMIC HIP SYSTEM (DHS) HAD BROKEN OFF WHEN THE INITIAL SURGERY OCCURRED. FRAGMENTS WERE GENERATED AND WERE REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO SURGICAL DELAY. NO PATIENT CONSEQUENCE. THIS COMPLAINT INVOLVES ONE (1) DEVICE. THIS REPORT IS FOR (1) DHS®/DCS® IMPACTOR. THIS REPORT IS 1 OF 1 FOR (B)(4).
Patient problems: Hematoma
MAUDE report 11132729 ↗MalfunctionDec 30, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT ON AN UNKNOWN DATE DURING AN UNKNOWN PROCEDURE, THE DYNAMIC HIP AND CONDYLAR SCREW SYSTEM (DHS/DCS) IMPACTOR BROKE OFF DURING USE. IT IS UNKNOWN IF THE PROCEDURE WAS COMPLETED SUCCESSFULLY. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. THERE WAS NO PATIENT IMPACT. THIS COMPLAINT INVOLVES TWO (2) DEVICES. THIS REPORT IS FOR (1) DHS®/DCS® IMPACTOR. THIS REPORT IS 1 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11098279 ↗MalfunctionDec 30, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT ON AN UNKNOWN DATE DURING AN UNKNOWN PROCEDURE, THE DYNAMIC HIP AND CONDYLAR SCREW SYSTEM (DHS/DCS) IMPACTOR BROKE OFF DURING USE. IT IS UNKNOWN IF THE PROCEDURE WAS COMPLETED SUCCESSFULLY. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. THERE WAS NO PATIENT IMPACT. THIS COMPLAINT INVOLVES TWO (2) DEVICES. THIS REPORT IS FOR (1) DHS®/DCS® IMPACTOR. THIS REPORT IS 2 OF 2 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11098239 ↗MalfunctionFeb 19, 2020Break; Break
IT WAS REPORTED THAT ON (B)(6) 2020, DURING AN OPEN REDUCTION INTERNAL FIXATION FOR A PATIENT WITH A RIGHT HIP FRACTURE, THE DYNAMIC HIP, AND CONDYLAR SCREW SYSTEM ( DHS/ DCS) COUPLING SCREW AND THE DHS/ DCS GUIDE SHAFT BECAME BENT AND UNUSABLE UPON INSERTION OF THE UNKNOWN DHS PLATE OVER THE UNKNOWN LAG SCREW. THE SURGEON TRIED A NEW COUPLING SCREW WHICH SUBSEQUENTLY BECAME BENT AS WELL. THE DHS/ DCS IMPACTOR WAS ALSO DAMAGED DURING THIS PROCESS. A PORTION OF THE GRAY TIP CHIPPED OFF DURING IMPACTION. THE SURGEON HAD TO USE BACKUP INSTRUMENTATION FROM A SECOND INSTRUMENT TRAY TO COMPLETE THE PROCEDURE. THERE WAS A SURGICAL DELAY OF TEN TO FIFTEEN ( 10- 15 ) MINUTES. THE GENERATED FRAGMENTS WERE REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION. THERE WAS NO PATIENT CONSEQUENCE REPORTED. CONCOMITANT DEVICES REPORTED: UNKNOWN DHS PLATE ( PART# UNKNOWN, LOT# UNKNOWN, QUANTITY 1). UNKNOWN LAG SCREW ( PART# UNKNOWN, LOT# UNKNOWN, QUANTITY 1). THIS REPORT IS FOR ONE (1) DHS®/DCS® IMPACTOR. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9727936 ↗MalfunctionFeb 26, 2019Break; Break
IT WAS REPORTED THAT ON (B)(6) 2019, DURING AN UNKNOWN SURGERY, THE PLASTIC TIP OF THE DYNAMIC HIP AND CONDYLAR SYSTEM (DHS/DCS) IMPACTOR BROKE DURING REGULAR USE TO IMPACT DYNAMIC HIP SCREW PLATE TO BONE. THE SURGEON PROCEEDED TO USED A BONE TAMP TO IMPACT THE PLATE TO BONE AFTER THE DYNAMIC HIP SCREW (DHS) IMPACTOR BROKE. FRAGMENTS WERE REMOVED EASILY WITHOUT ADDITIONAL INTERVENTION. THERE WAS NO SURGICAL DELAY AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. PATIENT STATUS WAS UNKNOWN. CONCOMITANT DEVICES: PLATE (PART UNKNOWN, LOT UNKNOWN, QUANTITY 1). THIS REPORT IS FOR ONE (1) DHS/DCS IMPACTOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8370440 ↗MalfunctionOct 31, 2018Break; Break
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: DURING AN UNKNOWN PROCEDURE ON (B)(6) 2018, THE DYNAMIC HIP SCREW (DHS) PLATE IMPACTOR BROKE. THE PROCEDURE WAS COMPLETED USING A SIMILAR INSTRUMENT. PATIENT STATUS IS UNKNOWN. THIS REPORT IS FOR A DHS®/DCS® IMPACTOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8025042 ↗MalfunctionJun 13, 2018Break; Break
IT WAS REPORTED DURING AN UNKNOWN PROCEDURE ON (B)(6) 2018, WHILE USING THE MALLET AND IMPACTOR TO PUSH THE DHS PLATE TO THE BONE, A PIECE OF THE GRAY PLASTIC IMPACTOR BROKE OFF. THE PIECE WAS RETRIEVED EASILY WITHOUT ADDITIONAL INTERVENTION, AND THE IMPACTOR WAS STILL USABLE ENOUGH TO FINISH THE CASE. THERE WAS NO PATIENT IMPACT. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO DELAY. CONCOMITANT DEVICE(S) REPORTED: IMPACTION INST: HAMMER/MALLET: TR (PART #: UNKNOWN, LOT #: UNKNOWN, QTY: 1) DHS/DCS PLATE (PART #: UNKNOWN, LOT #: UNKNOWN, QTY: 1). THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7597354 ↗
FDA clearance and classification
The FDA regulates product code HWA (impactor) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the DHS 338.28
Has the DHS 338.28 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10886982193308), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the DHS 338.28?
The FDA's MAUDE database lists 11 adverse event reports for this device, received between Jun 13, 2018 and Apr 2, 2025. In those reports, the most common specific device problems are “Break” (7), “Crack” (1) and “Device-Device Incompatibility” (1); the most common patient problem is “Hematoma” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the DHS 338.28?
None of the reports are classified as deaths, 1 as an injury and 10 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the DHS 338.28 FDA approved?
Devices of this type (product code HWA) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Synthes GmbH.
Who makes the DHS 338.28, and is it still sold?
The FDA's device database lists Synthes GmbH as the company responsible for it (brand DHS, model 338.28). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other IMPACTOR devices
- PINNACLE 2217-50-041Depuy (Ireland) · IMPACTOR4,276 reports
- ATTUNE 2544-01-006Depuy (Ireland) · IMPACTOR1 recall2,528 reports
- ATTUNE 2544-01-003Depuy (Ireland) · IMPACTOR1 recall1,491 reports
- ATTUNE 2544-01-017Depuy (Ireland) · IMPACTOR1 recall1,454 reports
- ATTUNE 2544-01-004Depuy (Ireland) · IMPACTOR1 recall873 reports
- DURALOC 2360-71-000Depuy Orthopaedics, Inc. · IMPACTOR715 reports
- SPECIALIST 2581-11-000Depuy (Ireland) · IMPACTOR703 reports
- INHANCE 6205-10-103Depuy (Ireland) · IMPACTOR334 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page