NA 357.378Recalls & reported problems
Synthes GmbH · HELICAL BLADE EXTRACTOR · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10886982196095), received between Oct 22, 2018 and Mar 26, 2021 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility2
- Break1
- Component Missing1
- Material Twisted/Bent1
- Mechanical Problem1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
- No Patient Involvement1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 26, 2021Break; Break
IT WAS REPORTED THAT, THE HELICAL BLADE EXTRACTOR COLD WELDED WHILE USING FOR EXTRACTION OF HELICAL BLADE, INSERTED DRILL SLEEVES BROKE OFF AND PERIARTICULAR PROX HUMERUS PLATE LOCKING HOLE WAS STRIPPED AFTER INSERTING CORTICAL SCREW. SURGICAL DELAY AND PROCEDURE OUTCOME IS UNKNOWN. NO PATIENT CONSEQUENCE. THIS REPORT IS FOR ONE (1) HELICAL BLADE EXTRACTOR. THIS IS REPORT 2 OF 4 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11576128 ↗MalfunctionDec 11, 2019Mechanical Problem; Component Missing; Material Twisted/Bent; Mechanical Problem; Component Missing; Material Twisted/Bent
IT WAS REPORTED THAT ON (B)(6) 2019, THE HELICAL BLADE EXTRACTOR WAS FOUND NOT FUNCTIONING DURING REVERSE LOGISTICS AUDIT OF RETURNED DEVICE AT MILLSTONE. THERE WAS NO PATIENT INVOLVEMENT AND NO ADDITIONAL INFORMATION IS AVAILABLE. DURING MANUFACTURER'S INVESTIGATION ON (B)(6) 2019 IT WAS OBSERVED THAT INTERNAL THREAD PORTION OF THE BLADE INTERFACE SLEEVE AT THE PROXIMAL SIDE WAS FOUND TO BE STRIPPED/WORN WHICH CAN ALSO IMPACT THE FUNCTIONALITY OF THE DEVICE. THIS REPORT IS FOR ONE (1) HELICAL BLADE EXTRACTOR. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Patient Involvement
MAUDE report 9454218 ↗MalfunctionOct 14, 2019Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE THE DAMAGED INSTRUMENT WOULD NOT ATTACH PROPERLY DURING SURGERY. NO FURTHER PATIENT INFORMATION. THIS REPORT IS FOR ONE (1) HELICAL BLADE EXTRACTOR. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9184881 ↗MalfunctionOct 22, 2018Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT ON (B)(6) 2018, DURING REMOVAL OF A TROCHANTERIC FIXATION NAIL (TFN), THE HELICAL BLADE HAS BECOME STUCK ON THE CONNECTING SCREW AND EXTRACTION INSTRUMENT. THERE WAS NO INFORMATION GIVEN ON WHY THE IMPLANT WAS BEING REMOVED OR IF ANYTHING WAS IMPLANTED IN PLACE OF IT. THE CASE WAS ABLE TO CONTINUE AS THE BLADE HAD BEEN REMOVED. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO SURGICAL DELAY. THE PATIENT WAS FINE AFTER THE SURGERY. THIS REPORT IS FOR ONE (1) HELICAL BLADE EXTRACTOR. THIS IS REPORT 3 OF 3 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7993329 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page