NA 357.418Recalls & reported problems
Synthes GmbH · PERCUTANEOUS INSERTION HANDLE F/TROCHANTERIC FIXATION NAILS · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982196415), received between Aug 10, 2018 and Aug 10, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 10, 2018Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT ON (B)(6) 2018 PATIENT UNDERWENT A TROCHANTERIC FIXATION NAIL (TFN) INSERTION PROCEDURE. DURING THE SURGERY, THE HELICAL BLADE WOULD NOT GO THROUGH THE NAIL. THE SURGEON ATTEMPTED TO INSERT THE HELICAL BLADE MULTIPLE TIMES. HOWEVER, THE BLADE WOULD NOT GO THROUGH THE NAIL. THE SURGEON FINALLY DECIDED TO CHANGE THE INSERTION HANDLE AND CONNECTING SCREW AND WAS ABLE TO SUCCESSFULLY INSERT THE HELICAL BLADE. A SECOND HELICAL BLADE WAS USED AS THE FIRST HELICAL BLADE WAS SCRATCHED FROM TRYING TO INSERT IT. THERE WAS A TWO-HOUR SURGICAL DELAY. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH SATISFACTORY PATIENT OUTCOME. CONCOMITANT DEVICE REPORTED: TFN NAIL (PART #: UNKNOWN, LOT #: UNKNOWN, QUANTITY: 1). THIS REPORT IS FOR ONE (1) PERCUTANEOUS INSERTION HANDLE F/TROCHANTERIC FIXATION NAILS. THIS IS REPORT 1 OF 3 FOR (B)(4).
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7774362 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page