Skip to content

NA 395.923Recalls & reported problems

Synthes GmbH · 6.0MM/5.0MM THREADED DRILL SLEEVE-LONG · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10886982200945), received between Aug 13, 2018 and Mar 18, 2024 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Material Deformation” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Deformation4
  • Device-Device Incompatibility2

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Patient Involvement1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 18, 2024Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT ON AN UNKNOWN DATE, THEY WERE DOING EXTRA-LARGE EXTERNAL FIXATOR CASE WITH HA COAT UPON INSERTION HA COAT THROUGH THE SLEEVE THEY GOT CUT INSIDE. THE PATIENT WAS NOT AFFECTED, AND SURGERY WAS COMPLETED SUCCESSFULLY. THIS REPORT IS FOR ONE (1) 6.0MM/5.0MM THREADED DRILL SLEEVE-LONG THIS IS REPORT 1 OF 2 FOR COMPLAINT (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18924612 ↗
  • MalfunctionSep 28, 2023Material Deformation; Material Deformation

    IT WAS REPORTED THAT ON AN UNKNOWN DATE THE SLEEVE IS BENT AND WEDGED SHANZ PIN. IT IS UNABLE TO SPECTATE. THERE WAS NO SURGICAL DELAY. THERE WAS NO PATIENT CONSEQUENCES. THIS REPORT IS FOR ONE (1) 6.0MM/5.0MM THREADED DRILL SLEEVE-LONG THIS IS REPORT 1 OF 2 FOR COMPLAINT (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17836495 ↗
  • MalfunctionSep 28, 2023Material Deformation; Material Deformation

    IT WAS REPORTED THAT ON AN UNKNOWN DATE THE SLEEVE IS BENT AND WEDGED SHANZ PIN. IT IS UNABLE TO SPECTATE. THERE WAS NO SURGICAL DELAY. THERE WAS NO PATIENT CONSEQUENCES. THIS REPORT IS FOR ONE (1) 6.0MM/5.0MM THREADED DRILL SLEEVE-LONG. THIS IS REPORT 1 OF 2 FOR COMPLAINT (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17836224 ↗
  • MalfunctionMay 25, 2023Material Deformation; Material Deformation

    IT WAS REPORTED, THAT ON AN UNKNOWN DATE. THE ITEMS IN QUESTION WERE DISCOVERED, TO BE BENT AND DAMAGED. THIS WAS OBSERVED, POST-OP WHILE THE ITEMS WERE BEING CLEANED IN STERILE PROCESSING. THERE WAS NO REPORTED PATIENT INVOLVEMENT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A 6.0MM/5.0MM THREADED DRILL SLEEVE-LONG. THIS IS REPORT 3 OF 6 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17007187 ↗
  • MalfunctionMay 25, 2023Material Deformation; Material Deformation

    IT WAS REPORTED, THAT ON AN UNKNOWN DATE. THE ITEMS IN QUESTION WERE DISCOVERED TO BE BENT AND DAMAGED. THIS WAS OBSERVED, POST-OP WHILE THE ITEMS WERE BEING CLEANED IN STERILE PROCESSING. THERE WAS NO REPORTED PATIENT INVOLVEMENT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A 6.0MM/5.0MM THREADED DRILL SLEEVE-LONG. THIS IS REPORT 6 OF 6 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17007186 ↗
  • MalfunctionAug 13, 2018Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT A SCREW WAS STUCK IN A LONG-THREADED DRILL SLEEVE. IT WAS FOUND OUT AT THE STERILE PROCESSING DEPARTMENT ON (B)(6) 2018. THERE WAS NO PATIENT AND PROCEDURE INVOLVED. THIS REPORT IS FOR ONE (1) 6.0MM/5.0MM THREADED DRILL SLEEVE-LONG. THIS IS REPORT 1 OF 2 FOR COMPLAINT (B)(4).

    Patient problems: No Patient Involvement

    MAUDE report 7778610 ↗