NA 402.894Recalls & reported problems
Synthes GmbH · 2.7MM TI CORTEX SCREW SLF-TPNG WITH T8 STARDRIVE RECESS 34MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982206817), received between Sep 25, 2020 and Sep 25, 2020 — classified as 2 injuries.
The most frequently reported specific device problem is “Off-Label Use” (2 reports).
4 other recalls cover devices cleared under the same FDA submission (K050110, K063049, K112583, K962616); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Off-Label Use2
Patient problems
- Injury2
- No Code Available2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 25, 2020Off-Label Use; Off-Label Use
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2020 DURING AN OPEN REDUCTION FIBULA AND TIBIA PROCEDURE, THE SURGEON IMPLANTED LATERAL DISTAL FIBULAR PLATES AND USED 2.7MM CORTICAL SCREWS IN THE BODY OF THE PLATE INSTEAD OF THE INDICATED 3.5MM SCREWS. AFTER A PREVIOUS PROCEDURE, THE SURGEON DIRECTED THE STAFF TO RETAIN 3.5MM SCREWS AND THEY WERE SENT TO BE STERILIZED. THE SURGEON BEGAN THE PATIENT'S PROCEDURE WITHOUT THE 3.5MM BEING AVAILABLE AS THEY WERE STILL BEING STERILIZED. AFTER BEING ADVISED THAT USING THE 2.7MM CORTICAL SCREWS COULD GENERATED COMPLICATIONS IN THE PATIENT, THE SURGEON PROCEEDED TO IMPLANT THE 2.7MM CORTICAL SCREWS. THERE IS NO FURTHER INFORMATION AVAILABLE. THIS REPORT IS FOR ONE (1) 2.7MM TI CORTEX SCREW SLF-TPNG WITH T8 STARDRIVE RECESS 34MM. THIS IS REPORT 9 OF 10 FOR (B)(4).
Patient problems: Injury; No Code Available
MAUDE report 10588511 ↗InjurySep 25, 2020Off-Label Use; Off-Label Use
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2020 DURING AN OPEN REDUCTION FIBULA AND TIBIA PROCEDURE, THE SURGEON IMPLANTED LATERAL DISTAL FIBULAR PLATES AND USED 2.7MM CORTICAL SCREWS IN THE BODY OF THE PLATE INSTEAD OF THE INDICATED 3.5MM SCREWS. AFTER A PREVIOUS PROCEDURE, THE SURGEON DIRECTED THE STAFF TO RETAIN 3.5MM SCREWS AND THEY WERE SENT TO BE STERILIZED. THE SURGEON BEGAN THE PATIENT'S PROCEDURE WITHOUT THE 3.5MM BEING AVAILABLE AS THEY WERE STILL BEING STERILIZED. AFTER BEING ADVISED THAT USING THE 2.7MM CORTICAL SCREWS COULD GENERATED COMPLICATIONS IN THE PATIENT, THE SURGEON PROCEEDED TO IMPLANT THE 2.7MM CORTICAL SCREWS. THERE IS NO FURTHER INFORMATION AVAILABLE. THIS REPORT IS FOR ONE (1) 2.7MM TI CORTEX SCREW SLF-TPNG WITH T8 STARDRIVE RECESS 34MM. THIS IS REPORT 5 OF 10 FOR (B)(4).
Patient problems: Injury; No Code Available
MAUDE report 10587925 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K050110, K063049, K112583, K962616. One submission often covers many models, so check the product and lot details in each record.
- Z-2389-2016 · Jun 28, 2016 · TerminatedSynthes 2.4mm Titanium Locking Screws Self-Tapping with Stardrive Recess 12mm, Synthes 2.4mm Titanium Locking Screws Self-Tapping with Stardrive Recess 12mm, Plate, Fixation, Bone,
- Z-0323-2016 · Nov 2, 2015 · Terminated2.4MM locking screw SLF-TPNG with Stardrive Recess 18 mm. Intended for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone frag
- Z-0167-2016 · Oct 6, 2015 · Terminated2.7 mm Locking Screw SLF-TPNG with T8 Stardrive Recess 12mm. The Synthes modular Mini Fragment LCP System is intended for fixation of fractures, osteotomies, nonunions, replantati
- Z-0380-2014 · Jul 31, 2013 · Terminated2.4 and 2.7 MM Locking Screw SLF-TPNG with T8 Stardrive Recess 12 MM Fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragmen
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page