LCP 422.226Recalls & reported problems
Synthes GmbH · TI LCP PROXIMAL LATERAL TIBIA PL 11 HOLES/260MM-RIGHT · Class 2 · Implant
All models of LCP (367)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982215147), received between May 3, 2017 and May 3, 2017 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- No Code Available1
- Nonunion/Delayed-union Bone Fracture1
- Unspecified Infection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 3, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT REVISION SURGERY ON (B)(6) 2017 FOR REMOVAL OF HARDWARE DUE TO INFECTION AND A DELAYED UNION. THE PATIENT WAS ORIGINALLY IMPLANTED WITH ONE (1) TITANIUM LOCKING COMPRESSION PLATE-PROXIMAL LATERAL TIBIA AND EIGHT (8) SCREWS ON (B)(6) 2017 DURING AN OPEN REDUCTION INTERNAL FIXATION (ORIF) OF THE TIBIA TO TREAT A FRACTURE. ON AN UNKNOWN DATE AFTER THE SURGERY THE PATIENT DEVELOPED AN INFECTION AND A MASS FORMED AT HIS KNEE. IT IS UNKNOWN WHETHER THE PATIENT HAD PAIN RELATED TO THE DIAGNOSIS OR WHEN HE SOUGHT MEDICAL ATTENTION. DURING THE REVISION THE PLATE AND EIGHT (8) SCREWS WERE REMOVED WHOLE AND INTACT AND THE MASS AT THE PATIENT¿S KNEE WAS DRAINED, IRRIGATED AND DEBRIDED. THE PATIENT RECEIVED ANTIBIOTICS. NEW HARDWARE WAS NOT IMPLANTED. THERE WAS NO SURGICAL DELAY. NO HARM WAS REPORTED TO THE PATIENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THIS REPORT IS 1 OF 9 FOR COM-(B)(4).
Patient problems: No Code Available; Nonunion/Delayed-union Bone Fracture; Unspecified Infection
MAUDE report 6540682 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.