Skip to content

LCP 422.254SRecalls & reported problems

Synthes GmbH · TI LCP DISTAL FEMUR PLATE 9 HOLES/236MM/RIGHT-STERILE · Class 2 · Implant

All models of LCP (367)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982215413), received between Jun 13, 2025 and Jun 13, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 13, 2025Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT ON (B)(6) 2025, THE PATIENT UNDERWENT A REMOVAL SURGERY DISTAL FEMUR FRACTURE WITH THE EXTRACT SCREW. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO DELAY. THE EXTRACT-SCREW BROKE AND REMAINED INSIDE THE LOCKING HEAD. THEREFORE, THE SURGEON ATTEMPTED TO SEPARATE THE PLATE FROM SCREW WITH THE CARBIDE DRILL, BUT THE EXTRACT-SCREW WAS SO HARD THAT IT COULD NOT BE CUT AWAY AT ALL. THE SURGEON GAVE UP ON REMOVAL AND COMPLETED THE SURGERY LEAVING ONE PLATE AND SCREW IN PLACE. THE SURGEON MENTIONED THAT THE BROKEN PART OF THE EXTRACT-SCREW REMAINED IN THE SCREW HEAD, MAKING IT IMPOSSIBLE TO CUT IT OUT WITH THE CARBIDE DRILL, AND THAT HE COULD NOT SEPARATE THE PLATE FROM THE SCREW AND HAD TO CHOOSE TO LET IT REMAIN IN THE BODY. THE SURGEON ALSO MENTIONED THAT HE USED A SHORT-HANDLE EXTRACTION DRILL AND ASSUMED THAT THE POSSIBILITY OF BREAKAGE WAS LOW.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22205567 ↗

Other PLATE, FIXATION, BONE devices

All PLATE, FIXATION, BONE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page