NA 456.308Recalls & reported problems
Synthes GmbH · 11.0MM TI HELICAL BLADE 115MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982226778), received between Apr 5, 2017 and Apr 5, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Failure to Advance” (1 report).
7 other recalls cover devices cleared under the same FDA submission (K011857); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Failure to Advance1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 5, 2017Failure to Advance; Failure to Advance
IT WAS REPORTED THAT A PATIENT UNDERWENT A TROCHANTERIC FIXATION NAIL (TFN) PROCEDURE FOR INTERTROCHANTERIC HIP FRACTURE ON (B)(6) 2017. UPON INSERTION OF HELICAL BLADE THROUGH THE NAIL, IT WAS NOTICED THAT THE PLUNGER BUILT INTO THE NAIL WAS ADVANCED, PREVENTING THE HELICAL BLADE FROM PASSING THROUGH THE NAIL. THE SURGEON PULLED THE PLUNGER BACKED UP AND CONTINUED TO INSERT HELICAL BLADE BUT IT WOULD NOT ADVANCE. HE REPOSITIONED GUIDE WIRE AND ATTEMPTED ONE MORE TIME WITH SAME RESULTS, THE HELICAL BLADE WOULD NOT ADVANCE. IT WAS DETERMINED BEST TO REMOVE THE NAIL AND HELICAL BLADE THAT WAS NOT ADVANCING AND REPLACED IT WITH ANOTHER OF THE SAME SIZE. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH A TIME DELAY OF 15 MINUTES BECAUSE OF THE ATTEMPTS, REMOVAL, REASSEMBLY AND REINSERTIONS. THERE WAS NO HARM TO PATIENT AND THE PATIENT OUTCOME IS NOT AVAILABLE. THIS REPORT IS FOR ONE (1) HELICAL BLADE. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6460810 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K011857. One submission often covers many models, so check the product and lot details in each record.
- Z-0604-2018 · Jul 21, 2017 · Terminated11MM/130 Degree Titanium Trochanteric Fixation Nail 380MM/Right, Sterile
- Z-0375-2016 · Nov 2, 2015 · TerminatedTrochanteric Fixation Nail- Advanced System-11MM/130 DEG TI CANN TFNA 420MM/Right Sterile (The TFN-ADVANCED Proximal Femoral Nailing System) The TFN-ADVANCED Proximal Femoral Naili
- Z-0219-2015 · Oct 29, 2014 · Terminated10 mm/135 degree Titanium Cannulated Trochanteric Fixation Nail 170 MM - Sterile: intended to treat stable and unstable fractures of the proximal femur
- Z-0387-2014 · Jul 31, 2013 · TerminatedLarge Buttress Compression Nut For Blade Guide Sleeve TFN The Synthes Large Buttress Compression Nut For Blade Guide Sleeve TFN is intended to treat stable and unstable pertrocha
- Z-0452-2014 · Jul 30, 2013 · TerminatedTitanium Trochanteric Fixation Nail (TFN)System Intended to treat stable and unstable fractures of the proximal femur.
- Z-0474-2014 · Jul 30, 2013 · TerminatedSynthes Trochanteric Fixation Nail As part of the Synthes Trochanteric Fixation Nail (TFN) System, the TFN Nail is intended to treat stable and unstable fractures of the proximal
- Z-2058-2013 · Nov 2, 2012 · TerminatedSynthes Trauma Nail System. The devices are indication for bone fixation.
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page