NA 02.221.102Recalls & reported problems
Synthes GmbH · 3.5MM VA PPFX GT RING ATTCHMT PLATE/LARGE/RIGHT · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982276001), received between Sep 4, 2024 and Jan 22, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Device-Device Incompatibility1
- Material Twisted/Bent1
Patient problems
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 22, 2026Material Twisted/Bent
IT WAS REPORTED THAT VA LOCKING PPFX GREATER TROCHANTER RING AND 3.5 VAL GREAT TROCH RNG ATCH PL/LRG/RT AND 3.5 VAL GREAT TROCH RING ATTACH PL/SM/LT WERE INVOLVED IN AN EVENT. DURING A PROCEDURE TO REPAIR A FRACTURE AROUND A TOTAL HIP, ATTEMPTS TO ATTACH THE SMALL GT RING ATTACHMENT PLATE TO THE VA-LCP PPFX PROXIMAL FEMUR PLATE WERE UNSUCCESSFUL DUE TO STRIPPED SCREWS ON THE GT RING ATTACHMENT. FURTHER ATTEMPTS TO REMOVE SCREWS FROM THE LARGE GT RING PLATE ALSO RESULTED IN STRIPPED SCREWS. ALL SCREWS FROM THE GT RING PLATES (FOUR IN TOTAL) WERE FOUND TO BE STRIPPED, PREVENTING ATTACHMENT. THE PROCEDURE WAS COMPLETED WITHOUT THE GT RING ATTACHMENT PLATE, RESULTING IN A DELAY OF APPROXIMATELY 10 MINUTES. THERE WAS NO REPORTED PATIENT HARM OR CONSEQUENCE, AND THE PATIENT OUTCOME WAS GOOD.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24143861 ↗MalfunctionSep 4, 2024Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE ITEMS FAILED TO CONNECT DURING SURGERY, FORCING SURGEONS TO USE DIFFERENT PLATE. PROCEDURE AND PATIENT OUTCOME WERE UNKNOWN. THIS REPORT IS FOR ONE 3.5 VAL GREAT TROCH RNG ATCH PL/LRG/RT. THIS IS REPORT 2 OF 4 FOR (B)(4).
Patient problems: Insufficient Information
MAUDE report 20137554 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗