Skip to content

NA 02.221.102SRecalls & reported problems

Synthes GmbH · 3.5MM VA PPFX GT RING ATTCHMT PLATE/LARGE/RIGHT/STERILE · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982276025), received between Jan 14, 2025 and Oct 15, 2025 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility2

Patient problems

  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 15, 2025Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THE 10 HOLE RIGHT VA PPFX STANDARD PLATE OPENED WITH SMALL RIGHT VA GT RING ATTACHMENT PLATE. AFTER REPEATED ATTEMPTS THE SCRUB NURSE SURGEON AND REGISTRAR COULD NOT CONNECT THE TWO. THIS WAS DONE ON THE TABLE NOT IN THE PATIENT. IT WAS LINED UP PERFECTLY AS FAR AS I COULD SEE BUT THE CONNECTING SCREW ON THE GT RING PLATE SEEMED TOO BIG FOR THE HOLE IN THE PPFX STANDARD PLATE NO MATTER HOW MUCH PERSEVERANCE OR ANTI CLOCKWISE TURNS TO TRY AND GET IT TO DROP INTO PLACE OR ALTERING THE ANGLE OF THE SCREWDRIVER/SCREW WORKED. AFTER THIS A SECOND PFPX PLATE 11 HOLE THIS TIME AND A SECOND GT RING PLATE LARGE RIGHT WERE OPENED TO TRY AND ELIMINATE ISSUES WITH EITHER THE HOLE OR THE CONNECTION SCREW. NO COMBINATION OF THESE IMPLANTS WERE ABLE TO BE PUT TOGETHER. A SECOND SCRUB NURSE CAME TO THE TABLE AND TRIED TO ASSEMBLE THE PRODUCTS FOR A FURTHER 30 MINUTES WHILE THE SURGEON CONTINUED WITH THE OPERATION. AFTER THE CASE WAS FINISHED, I ATTEMPTED TO ASSEMBLE THE PRODUCTS AND FAILED. THE SURGEON FINISHED THE OPERATION USING THE STANDARD PLATE ONLY BUT HAS SAID THE OPERATION AND OUTCOME COULD BE COMPROMISED DUE TO THE INABILITY TO ASSEMBLE THE PRODUCTS AND GAIN THE ADDITIONAL

    Patient problems: Insufficient Information

    MAUDE report 23280016 ↗
  • MalfunctionJan 14, 2025Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT THE PFFX GREATER TROCH ATTACHMENT PLATES WERE NOT SCREWING INTO PLATE. USER TRIED SEVERAL ATTACHMENTS AND SEVERAL PLATES. USER THOUGHT THERE WAS AN ISSUE WITH ONE OF THE ATTACHMENT PLATE SCREWS WHICH THEN DEFORMED SOME PLATES. DOCTOR PROCEEDED WITH SURGERY WITHOUT ATTACHMENT PLATE. SURGERY WAS DELAYED BY 10 MINUTES DUE TO REPORTED EVENT. PROCEDURE WAS COMPLETED SUCCESSFULLY. FRAGMENTS WERE NOT GENERATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21148481 ↗

Other Plate, fixation, bone devices

All Plate, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page