NA 04.112.823SRecalls & reported problems
Synthes GmbH · 2.7MM TI VA LCP HOOK PLATE SHORT/ 12MM/ RIGHT/ STERILE · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982279750), received between Jul 28, 2025 and Jul 28, 2025 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON (B)(6) 2025, THE PATIENT UNDERWENT AN UNKNOWN SURGERY FOR DISTAL CLAVICLE FRACTURE WITH THE PLATE AND THE SCREWS. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO DELAY. ON (B)(6) 2025, THE SALES REP VISITED THE HOSPITAL AFTER BEING INFORMED BY THE DISTRIBUTOR THAT THE PLATE WOULD BE REMOVED AND REPLACED WITH A VA CLAVICLE PLATE. AFTER LOOKING AT THE X-RAY, THE SALES REP CONFIRMED THAT THE FRACTURE WAS NEAR THE MOST PROXIMAL PLATE. THE SURGEON'S OPINION WAS THAT THE MOST PROXIMAL SCREW AND THE SCREW NEXT TO IT WERE INSERTED SO THAT THEY CONVERGED, WHICH CAUSED STRESS TO CONCENTRATE AND LEAD TO A SECONDARY FRACTURE. AFTER REMOVING THE PRODUCT, THE PATIENT WILL BE REFIXED WITH A VA CLAVICLE PLATE. THE DOCTOR'S OPINION ON THE RELATIONSHIP BETWEEN THIS INCIDENT AND THE PRODUCT: THE MOST PROXIMAL SCREW AND THE SECOND ROW OF VA 2.7 (04.211.016TS) WERE INSERTED SO THAT THEY CONVERGED, WHICH CAUSED STRESS TO CONCENTRATE AND LEAD TO A SECONDARY FRACTURE. PATIENT IS STABLE.
Patient problems: Bone Fracture(s)
MAUDE report 22629165 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.