Skip to content

NA 04.112.823SRecalls & reported problems

Synthes GmbH · 2.7MM TI VA LCP HOOK PLATE SHORT/ 12MM/ RIGHT/ STERILE · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982279750), received between Jul 28, 2025 and Jul 28, 2025 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Bone Fracture(s)1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2025, THE PATIENT UNDERWENT AN UNKNOWN SURGERY FOR DISTAL CLAVICLE FRACTURE WITH THE PLATE AND THE SCREWS. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO DELAY. ON (B)(6) 2025, THE SALES REP VISITED THE HOSPITAL AFTER BEING INFORMED BY THE DISTRIBUTOR THAT THE PLATE WOULD BE REMOVED AND REPLACED WITH A VA CLAVICLE PLATE. AFTER LOOKING AT THE X-RAY, THE SALES REP CONFIRMED THAT THE FRACTURE WAS NEAR THE MOST PROXIMAL PLATE. THE SURGEON'S OPINION WAS THAT THE MOST PROXIMAL SCREW AND THE SCREW NEXT TO IT WERE INSERTED SO THAT THEY CONVERGED, WHICH CAUSED STRESS TO CONCENTRATE AND LEAD TO A SECONDARY FRACTURE. AFTER REMOVING THE PRODUCT, THE PATIENT WILL BE REFIXED WITH A VA CLAVICLE PLATE. THE DOCTOR'S OPINION ON THE RELATIONSHIP BETWEEN THIS INCIDENT AND THE PRODUCT: THE MOST PROXIMAL SCREW AND THE SECOND ROW OF VA 2.7 (04.211.016TS) WERE INSERTED SO THAT THEY CONVERGED, WHICH CAUSED STRESS TO CONCENTRATE AND LEAD TO A SECONDARY FRACTURE. PATIENT IS STABLE.

    Patient problems: Bone Fracture(s)