The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 10886982316448), received between Mar 6, 2026 and Sep 17, 2026 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 3 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 2 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility4
  • Material Twisted/Bent3

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Insufficient Information2

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 17, 2026Device-Device Incompatibility

    It was reported on an unknown date, that during a surgical procedure utilizing the VOLT Distal Radius Plate, an issue was encountered with multiple locking screws failing to properly lock into the plate. Despite appropriate use of the designated guide block and following the recommended technique, the locking screws did not consistently engage and lock into the threaded holes of the plate as intended. Attempts were made to achieve proper screw engagement using the guide block; however, the screws continued to advance without achieving the expected locking mechanism. This resulted in difficulty obtaining secure screw-to-plate fixation and required removal of the plate. The product and associated instrumentation should be evaluated to determine whether there is a potential issue with the plate threads, locking screw threads, guide block alignment, or compatibility between the components.

    Patient problems: Insufficient Information

    MAUDE report 50805258 ↗
  • MalfunctionSep 17, 2026Device-Device Incompatibility

    It was reported on an unknown date, that during a surgical procedure utilizing the VOLT Distal Radius Plate, an issue was encountered with multiple locking screws failing to properly lock into the plate. Despite appropriate use of the designated guide block and following the recommended technique, the locking screws did not consistently engage and lock into the threaded holes of the plate as intended. Attempts were made to achieve proper screw engagement using the guide block; however, the screws continued to advance without achieving the expected locking mechanism. This resulted in difficulty obtaining secure screw-to-plate fixation and required removal of the plate. The product and associated instrumentation should be evaluated to determine whether there is a potential issue with the plate threads, locking screw threads, guide block alignment, or compatibility between the components.

    Patient problems: Insufficient Information

    MAUDE report 50805244 ↗
  • MalfunctionJun 1, 2026Device-Device Incompatibility

    IT WAS REPORTED MULTIPLE SCREWS WOULD NOT LOCK INTO THE PLATE. DIFFERENT LOCKING GUIDES AND TRAJECTORIES OF THE DRILL WAS TRIED. THEY ALSO TRIED A NEW PLATE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A FORTY-FIVE MINUTE DELAY, BUT IT WAS NOTED THE FIXATION WAS SUBOPTIMAL, BUT NOT OTHER MEDICAL INTERVENTION WAS NEEDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25350587 ↗
  • MalfunctionJun 1, 2026Device-Device Incompatibility

    IT WAS REPORTED MULTIPLE SCREWS WOULD NOT LOCK INTO THE PLATE. DIFFERENT LOCKING GUIDES AND TRAJECTORIES OF THE DRILL WAS TRIED. THEY ALSO TRIED A NEW PLATE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A FORTY-FIVE MINUTE DELAY, BUT IT WAS NOTED THE FIXATION WAS SUBOPTIMAL, BUT NOT OTHER MEDICAL INTERVENTION WAS NEEDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25350138 ↗
  • MalfunctionMar 9, 2026Material Twisted/Bent

    ADDITIONAL INFORMATION WAS RECEIVED AND STATES THAT: DEPTH GAUGES HAVE BEEN WORN DOWN AND RENDERED UNREADABLE. NEEDS TO BE REPLACED\PLATE BENDER HAS LOOSENED. NO PATIENT HARM AND SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24543892 ↗
  • MalfunctionMar 9, 2026Material Twisted/Bent

    ADDITIONAL INFORMATION WAS RECEIVED AND STATES THAT : DEPTH GAUGES HAVE BEEN WORN DOWN AND RENDERED UNREADABLE. NEEDS TO BE REPLACED\PLATE BENDER HAS LOOSENED. NO PATIENT HARM AND SURGICAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24543874 ↗
  • MalfunctionMar 6, 2026Material Twisted/Bent

    IT WAS REPORTED THAT SLOTTED NOSEPIECE FOR CABLE TENSIONER, LABEL SHEET PACK FOR MINI SUPPLEMENTAL SCREW RACK, SUPPLEMENTAL SCREW RACK W/LID FOR 1.5MM/2.0MM/2.4MM SCREWS, 2.4MM VOLT(TM) LOCKING SCREW 20MM T8, LABEL SHEET PACK FOR SMALL SUPPLEMENTAL SCREW RACKS, SUPPLEMENTAL SCREW RACK W/LID FOR 2.7/3.0/3.5/4.0MM SCREWS, GONIOMETER FOR PRE-OPERATIVE PLANNER, ALUMINUM CASE 220MM X 105MM X 40MM, STANDARD ALUMINUM CASE-HIGH RED, AND CUTTER F/TEN WERE REPORTED AS WORN DOWN AND RENDERED UNUSABLE DUE TO ROUTINE WEAR-AND-TEAR. THERE WAS NO REPORTED PATIENT OR USER HARM, AND NO SIGNIFICANT DELAY WAS NOTED. THE AFFECTED DEVICES WERE REQUESTED TO BE REPLACED AND ARE AVAILABLE FOR RETURN. THE COMPLAINT INVOLVES MULTIPLE REUSABLE INSTRUMENTS, AND THE ISSUE WAS NOT FOUND DURING USE BUT IS CONSIDERED END-OF-LIFE RELATED AS DEFINED IN THE INSTRUCTIONS FOR USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24532256 ↗

Other Screw, fixation, bone devices

All Screw, fixation, bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page