Skip to content

NA 04.500.150Recalls & reported problems

Synthes GmbH · 2.0MM CURVILINEAR DISTRACTOR R50/RIGHT · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10887587016771), received between Jun 26, 2023 and Jun 26, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 26, 2023Break; Break

    IT WAS REPORTED THAT DURING SURGERY ON (B)(6) 2023, THE ACTIVATION KNOB ON THE DISTRACTOR BODY BROKE OFF WHEN TRYING TO ACTIVATE. THE IMPLANTED DEVICE HAD TO BE REMOVED AND A NEW ONE IMPLANTED. THE SURGERY WAS COMPLETED SUCCESSFULLY, AND NO OTHER MEDICAL INTERVENTION WAS REQUIRED. THIS REPORT INVOLVES ONE 2.0MM CURVILINEAR DISTRACTOR R50/RIGHT. THIS IS REPORT 1 OF 1 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17198926 ↗

Other EXTERNAL MANDIBULAR FIXATOR AND/OR DISTRACTOR devices

All EXTERNAL MANDIBULAR FIXATOR AND/OR DISTRACTOR devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page