Skip to content

NorthStar PC1-524060Recalls & reported problems

Seaspine Orthopedics Corporation · Transition Ti Rod, 4.0mm to 6.0mm, 500mm · Class 2 · Implant

All models of NorthStar (24)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10889981199043), received between Oct 24, 2024 and Oct 24, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 24, 2024Fracture; Fracture

    ON (B)(6) 2024, A PATIENT UNDERWENT SPINAL SURGERY UTILIZING SEASPINE'S NORTHSTAR OCT POSTERIOR CERVICAL FUSION SYSTEM. DURING A FOLLOW-UP ON (B)(6) 2024, A ROD FRACTURE WAS OBSERVED. APPROXIMATELY A WEEK LATER THE OCCIPITAL PLATE TULIP WAS OBSERVED TO HAVE DISASSOCIATED WITH THE PLATE. BOTH DEVICES REMAIN IMPLANTED. IT IS UNKNOWN IF A REVISION SURGERY IS PLANNED. NO PATIENT INJURY WAS REPORTED. THIS REPORT IS FOR THE PC1-524060 TRANSITION TI ROD, 4.0MM TO 6.0MM, 500MM.

    Patient problems: Insufficient Information

    MAUDE report 20529992 ↗

Other Posterior cervical screw system devices

All Posterior cervical screw system devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page