Skip to content

CADD 21-2111-0402-51LRecalls & reported problems

Icu Medical, Inc. · Class 2

All models of CADD (123)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

3 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This ICU Medical CADD infusion pump has 122 adverse event reports, with no deaths or injuries. Reports most often describe the pump failing to infuse or sense, parts detaching or cracking, and alarm problems. Three open recalls name this device: two about false upstream occlusion alarms that can interrupt an active infusion, and one tied to software.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
127
Deaths reported
0
Injuries reported
0
Recalls naming it
3

Summary

The FDA's MAUDE database contains 127 adverse event reports that list this exact device (DI 15019517154986), received between Apr 12, 2023 and Sep 30, 2026 — classified as 127 malfunctions.

The most frequently reported specific device problem is “Failure to Infuse” (26 reports).

3 FDA recall records name this device's identifier, 3 still open.

4 other recalls cover devices cleared under the same FDA submission (K170982); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 2 reportsMar 2024: 3 reportsApr 2024: 4 reportsMay 2024: 1 reportsJun 2024: 3 reportsJul 2024: 2 reportsAug 2024: 2 reportsSep 2024: 6 reportsOct 2024: 9 reportsNov 2024: 12 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 2 reportsMar 2025: 4 reportsApr 2025: 1 reportsMay 2025: 5 reportsJun 2025: 7 reportsJul 2025: 6 reportsAug 2025: 6 reportsSep 2025: 3 reportsOct 2025: 4 reportsNov 2025: 4 reportsDec 2025: 5 reportsJan 2026: 1 reportsFeb 2026: 5 reportsMar 2026: 3 reportsApr 2026: 2 reportsMay 2026: 3 reportsJun 2026: 1 reportsJul 2026: 2 reportsAug 2026: 9 reportsSep 2026: 5 reportsOct 2026: 0 reports20242025202612
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Apr 10, 2025Class IOpen, Classified

    Affected pumps may trigger an erroneous (false) Upstream Occlusion Alarm under certain conditions, which will interrupt an active infusion. Interruption or delay of therapy can lead to serious patient injury or death.

    Z-1668-2025 · Root cause: Labeling design · Recall details · FDA record ↗

  2. Apr 10, 2025Class IOpen, Classified

    Affected pumps may trigger an erroneous (false) Upstream Occlusion Alarm under certain conditions, which will interrupt an active infusion. Interruption or delay of therapy can lead to serious patient injury or death.

    Z-1667-2025 · Root cause: Labeling design · Recall details · FDA record ↗

  3. Feb 27, 2024Class IOpen, Classified

    The CADD Solis VIP Ambulatory Infusion Pump is indicated for the following uses: " For intravenous, intraarterial, subcutaneous, intraperitoneal, perineural, surgical site, epidural space, or subarachnoid space infusion.

    Z-2420-2024 · Root cause: Software Manufacturing/Software Deployment · Recall details · FDA record ↗

Most reported problems

Device problems

  • Failure to Infuse26
  • Device Sensing Problem23
  • Detachment of Device or Device Component17
  • Device Alarm System12
  • Crack11
  • Failure to Sense11
  • Material Split, Cut or Torn8
  • Degraded7

Patient problems

  • No Clinical Signs, Symptoms or Conditions123
  • Insufficient Information5
  • Pain1

Recent adverse event reports

The 25 most recent of 127 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Device Sensing Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50951657 ↗
  • MalfunctionSep 9, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50698890 ↗
  • MalfunctionSep 7, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50650842 ↗
  • MalfunctionSep 3, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50594184 ↗
  • MalfunctionSep 2, 2026Crack

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50571827 ↗
  • MalfunctionAug 28, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50502939 ↗
  • MalfunctionAug 17, 2026Failure to Infuse

    It was reported that the pump displayed "error code 41786" during acceptance check. There were no patient involvement and harm.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50286598 ↗
  • MalfunctionAug 17, 2026Crack

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50279194 ↗
  • MalfunctionAug 17, 2026Infusion or Flow Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50276340 ↗
  • MalfunctionAug 13, 2026Failure to Sense

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50241029 ↗
  • MalfunctionAug 11, 2026Crack

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50203341 ↗
  • MalfunctionAug 5, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50148795 ↗
  • MalfunctionAug 4, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50133843 ↗
  • MalfunctionAug 4, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50133759 ↗
  • MalfunctionJul 31, 2026Crack

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50099593 ↗
  • MalfunctionJul 13, 2026Failure to Infuse

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25803184 ↗
  • MalfunctionJun 23, 2026Device Sensing Problem

    IT WAS STATED THAT THE PUMP DOESN'T IDENTIFY THE CARTRIDGE. THERE WAS NO PATIENT INVOLVEMENT. IT WAS OBSERVED DURING INSPECTION OF A RETURNED PUMP THAT DOWNSTREAM OCCLUSION SENSOR WAS DEFECTIVE. THE FAILURE MODE WAS FOUND BEFORE PATIENT USE. HOWEVER, IF THE ISSUE REOCCURS DURING INFUSION, IT WILL INTERRUPT THERAPY AND POTENTIALLY AFFECT THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25599497 ↗
  • MalfunctionMay 28, 2026Tear, Rip or Hole in Device Packaging; Material Split, Cut or Torn

    IT WAS REPORTED THAT THE PUMP EXHIBITED A TEAR IN THE MEMBRANE DURING TESTING. THERE WAS NO PATIENT INVOLVEMENT, NO INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25323075 ↗
  • MalfunctionMay 8, 2026Failure to Infuse; Key or Button Unresponsive/not Working

    IT WAS REPORTED THAT THE DEVICE HAS INTERMITTENT ERROR 45520 WHEN NOT IN USE. THERE WAS NO PATIENT INVOLVEMENT OR HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25129883 ↗
  • MalfunctionMay 6, 2026Device Sensing Problem

    IT WAS REPORTED THAT A CADD SOLIS HPCA PUMP EXPERIENCED A CONSTANT ALARM FOR UPSTREAM OCCLUSION WHEN THERE IS NO OCCLUSION. THE MALFUNCTION REPRESENTS A POTENTIAL RISK IF IT WERE TO RECUR DURING THERAPY AND THAT COULD LEAD TO INTERRUPTION OF INFUSION OR THERAPY DELIVERY. THERE WERE NO PATIENT INVOLVEMENT AND NO HARM REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25093666 ↗
  • MalfunctionApr 6, 2026Failure to Infuse; Obstruction of Flow

    THE PUMP DISPLAYED A DOWNSTREAM OCCLUSION ALARM, ALTHOUGH A THOROUGH CHECK OF THE LINE REVEALED NO ACTUAL OCCLUSION. THERE WAS NO PATIENT INVOLVEMENT OR HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24792371 ↗
  • MalfunctionApr 1, 2026Crack; Tear, Rip or Hole in Device Packaging

    IT WAS REPORTED PUMP HAD DOWNSTREAM OCCLUSION MEMBRANE DAMAGE. THIS EVENT OCCURRED DURING PREVENTIVE MAINTENANCE. PHOTO SAMPLES WAS PROVIDED, WHICH DEMONSTRATED THE SEAL WAS COMPROMISED. THERE WAS NO PATIENT INVOLVEMENT AND NO HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24757899 ↗
  • MalfunctionMar 19, 2026Device Sensing Problem

    IT WAS REPORTED THAT THE PUMP HAD ALARMED ¿DOWNSTREAM OCCLUSION¿ PRIOR TO PRIMING. NEW TUBING HAD BEEN TRIED, BUT THE ISSUE HAD BEEN DETERMINED TO BE WITH THE PUMP ITSELF. THERE WAS NO PATIENT INVOLVEMENT, AND NO PATIENT HARM REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24639911 ↗
  • MalfunctionMar 5, 2026Failure to Sense

    IT WAS REPORTED THAT THE DEVICE PRESENTS AN ALARM CASSETTE LOCKED BUT NOT LATCHED WHILE IT IS STILL LOCKED. THERE WAS NO REPORTED PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24522997 ↗
  • MalfunctionMar 3, 2026Device Alarm System

    IT WAS REPORTED THAT THE PUMP IS NOT PRIMING AND IS SENSITIVE TO UPSTREAM OCCLUSIONS. ALSO, DURING TESTING THE PUMP WAS FREQUENTLY ALARMING, AND SELF-CLEARING FOR UPSTREAM OCCLUSIONS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24495460 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K170982. One submission often covers many models, so check the product and lot details in each record.

  • Z-1662-2025 · Apr 10, 2025 · Open, Classified
    CADD Solis HSPCA Pump ***Updated 5/27/26*** Scope updated to apply specifically to customers using the wireless system. Affected products associated with the change in scope: PUM
  • Z-1681-2025 · Apr 10, 2025 · Open, Classified
    CADD-Solis Infusion Pump Models: 1) PUMP KIT, CADD-SOLIS, MDL 2110, V4.2, CE ENGLISH 1/EA, Model Number: 21-2111-0402-51; 2) PUMP KIT, CADD-SOLIS, MDL 2110, V4.2, YELLOW,
  • Z-0466-2025 · Jun 26, 2024 · Open, Classified
    smiths medical CADD-Solis Li-ion Rechargeable Battery Packs AC adapter, Model Number REF 21-0270-25, for use with the CADD-Solis infusion pumps
  • Z-0963-2023 · Dec 9, 2022 · Open, Classified
    CADD Administration Set, List Numbers: 1) REF 21-7300-24, 2) REF 21-7301-24 3) REF 21-7302-24, 4) REF 21-7321-24, 5) REF 21-7322-24, 6) REF 21-7323-24, 7) REF 21-7324-24, 8)

Other Pump, infusion, pca devices

All Pump, infusion, pca devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page