Skip to content

Access Estradiol 33540Recalls & reported problems

Beckman Coulter, Inc. · The Access Estradiol assay is a paramagnetic particle, chemiluminescent immunoassay for the quantitative determination of estradiol levels in human serum and plasma using the Access Immunoassay Systems. · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 15099590231408), received between Mar 22, 2018 and Nov 27, 2019 — classified as 2 injuries.

The most frequently reported specific device problem is “High Test Results” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • High Test Results1
  • Low Test Results1

Patient problems

  • No Code Available2
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 27, 2019Low Test Results; Low Test Results

    ON (B)(6) 2019, THE CUSTOMER REPORTED OBTAINING REPRODUCIBLE LOW ESTRADIOL (ACCESS ESTRADIOL) RESULTS FOR ONE PATIENT INVOLVING THE LABORATORY'S ACCESS 2 IMMUNOASSAY ANALYZER (PART NUMBER 81600N AND SERIAL NUMBER (B)(4) ON (B)(6) 2019. THE SAMPLE WAS TESTED TWICE ON THE SAME ANALYZER; RESULTS OBTAINED WERE 685 PG/ML (10:18 AM) AND 657 PG/ML (11:47 AM). THE CUSTOMER DID NOT PROVIDE A REFERENCE RANGE. THE BECKMAN COULTER ACCESS ESTRADIOL REFERENCE RANGE IS AS FOLLOWS: (B)(6) 2019. THERE WAS A REPORT OF CHANGE TO PATIENT TREATMENT BASED ON THE RESULTS. THE PATIENT WAS ADMINISTERED OVIDREL HCG. CUSTOMER REPORTED SUBSEQUENT EGG RETRIEVAL WAS PERFORMED ON (B)(6) 2019. CUSTOMER REPORTED EGG RETRIEVAL MAY HAVE BEEN PERFORMED TOO SOON AS PHYSICIAN NOTED SOME OF PATIENT'S EGGS WERE IMPACTED. THE CUSTOMER SUBSEQUENTLY REPORTED THAT THE PATIENT IS CURRENTLY PREGNANT. SYSTEM PERFORMANCE INDICATORS SUCH AS SYSTEM CHECK, CALIBRATION AND QUALITY CONTROL WERE PERFORMING WITHIN SPECIFICATIONS AND DID NOT INDICATE ANY ISSUES WITH THE SYSTEM. NO HARDWARE ERRORS WERE REPORTED AT THE TIME OF THE EVENT. CUSTOMER NOTED NO ISSUES WITH SAMPLE INTEGRITY. SAMPLE WAS COLLECTED IN 'GOLD TOP TUBE' AND WAS A FULL

    Patient problems: No Code Available

    MAUDE report 9386132 ↗
  • InjuryMar 22, 2018High Test Results; High Test Results

    THE CUSTOMER REPORTED OBTAINING NON-REPRODUCIBLE ELEVATED ESTRADIOL (ACCESS ESTRADIOL) RESULTS FOR TWELVE PATIENTS INVOLVING THE LABORATORY'S ACCESS 2 IMMUNOASSAY SYSTEM (SERIAL NUMBER (B)(4)). LATER THE SAME DAY, THE CUSTOMER REANALYZED THE PATIENTS' SAMPLES ON THE SAME ACCESS 2 IMMUNOASSAY SYSTEM AND OBTAINED LOWER RESULTS. THE INITIAL RESULTS WERE RELEASED FROM THE LABORATORY AND QUESTIONED BY THE PHYSICIAN. THE DOCTOR INFORMED THE LABORATORY TECHNICIAN THAT SOME OF THE DECISIONS WOULD HAVE BEEN DIFFERENT FOR SOME OF THESE PATIENTS DUE TO THE HIGHER ESTRADIOL RESULTS BUT ALL WOULD HAVE BEEN RELATED TO MEDICATION DOSAGES AND NOT PROCEDURES OR HARM. IT IS NOT CLEAR IF CHANGES TO MEDICATION DOSAGE ACTUALLY OCCURRED OR IF THE DOCTOR WAS SPECULATING THAT DOSAGE CHANGES WERE POSSIBLE WITH THE CHANGE IN ESTRADIOL RESULTS. THE NUMBER OF PATIENTS THAT MAY HAVE HAD A CHANGE TO TREATMENT WAS NOT PROVIDED. THE PATIENT REPORTS WERE CORRECTED TO THE LOWER RESULT THE SAME DAY. CALIBRATION AND SYSTEM CHECK WERE PERFORMING WITHIN ASSAY AND INSTRUMENT SPECIFICATIONS AT THE TIME OF THE EVENT. QUALITY CONTROL WAS STATED TO BE WITHIN THE CUSTOMER'S RANGES, BUT UPON EVALUATION LEVEL ONE AND TWO RECOV

    Patient problems: No Code Available; No Consequences Or Impact To Patient

    MAUDE report 7361278 ↗

FDA clearance and classification

The FDA regulates product code CHP (radioimmunoassay, estradiol) under 21 CFR 862.1260 as a Class I device. 21 CFR 862.1260 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Access Estradiol 33540

Has the Access Estradiol 33540 been recalled?

No FDA recall record in our data names this exact device identifier (DI 15099590231408), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Access Estradiol 33540?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 22, 2018 and Nov 27, 2019. In those reports, the most common specific device problems are “High Test Results” (1) and “Low Test Results” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Access Estradiol 33540?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Access Estradiol 33540 FDA approved?

Devices of this type (product code CHP) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Beckman Coulter, Inc.

Who makes the Access Estradiol 33540, and is it still sold?

The FDA's device database lists Beckman Coulter, Inc. as the company responsible for it (brand Access Estradiol, model 33540). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Radioimmunoassay, Estradiol devices

All Radioimmunoassay, Estradiol devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page