COULTER LH 500 (REF 178834)Recalls & reported problems
Beckman Coulter, Inc. · COULTER LH 500 Series System · Class 2
All models of COULTER LH (4)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 15099590265038), received between Aug 2, 2018 and Jul 7, 2021 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings2
- Output Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
- Test Result1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 7, 2021Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER REPORTED THAT PATIENT SAMPLES RECOVERED ERRATIC RESULTS FOR ALL PARAMETERS ON THEIR LH500 HEMATOLOGY INSTRUMENT. THE ERRONEOUS RESULTS WERE NOT REPORTED OUTSIDE THE LABORATORY. THERE WAS NO REPORT OF DEATH, INJURY, OR CHANGE TO PATIENT TREATMENT AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12130101 ↗MalfunctionJun 27, 2019Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER REPORTED INTERMITTENT HIGH PLATELET (PLT) RESULTS ON STARTUP, CONTROLS, AND PATIENT SAMPLES WHEN CYCLED ON THEIR COULTER LH 500 HEMATOLOGY ANALYZER. PATIENT DATA WAS REQUESTED BUT NOT PROVIDED FOR THIS EVENT. THE FIELD SERVICE ENGINEER (FSE) CONFIRMED THAT THERE WERE NO ERRONEOUS PLATELET RESULTS RELEASED OUT OF THE LABORATORY. THERE WAS NO DEATH, INJURY OR CHANGE TO PATIENT TREATMENT DUE TO THIS EVENT. INFORMATION ON WHETHER THE HIGH PLT RESULTS WERE FLAGGED WAS REQUESTED BUT COULD NOT BE CONFIRMED. THE FSE DID NOT KNOW IF THE RESULTS IN QUESTION WERE FLAGGED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8742106 ↗MalfunctionAug 2, 2018Output Problem; Output Problem
THE CUSTOMER REPORTED THAT THEIR COULTER LH 500 HEMATOLOGY ANALYZER WAS GENERATING ERRONEOUSLY HIGH PLATELET (PLT) RESULTS ON PATIENT SAMPLES. THE CUSTOMER HAS NOT REPORTED ANY CHANGE OR EFFECT TO PATIENT TREATMENT AS A RESULTS OF THIS EVENT.
Patient problems: Test Result
MAUDE report 7745077 ↗
Other Counter, Differential Cell devices
- Cytomics FC500 UPS (CXP)Beckman Coulter, Inc. · Counter, Differential Cell1,196 reports
- CELL-DYN 08H67-01Abbott Laboratories · Counter, differential cell6 recalls269 reports
- Alinity 09P6801Abbott Laboratories · Counter, differential cell2 recalls96 reports
- FACSCanto 338960Becton, Dickinson And Company · Counter, differential cell1 recall117 reports
- Cytomics FC500 UPS (MPL)Beckman Coulter, Inc. · Counter, Differential Cell141 reports
- CELL-DYN 08H00-01Abbott Laboratories · Counter, differential cell1 recall90 reports
- CELL-DYN 09H39-01Abbott Laboratories · Counter, differential cell123 reports
- BD Multitest 662995Becton, Dickinson And Company · Counter, differential cell2 recalls1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page