COULTER AcT 5diff (REF 6605581)Recalls & reported problems
Beckman Coulter, Inc. · COULTER AcT 5diff Hematology Analyzer · Class 2
All models of COULTER AcT (5)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 15099590576462), received between Oct 20, 2018 and Oct 20, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Output Problem” (1 report).
1 other recall cover devices cleared under the same FDA submission (K992511); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Output Problem1
Patient problems
- Test Result1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2018Output Problem; Output Problem
THE CUSTOMER REPORTED THAT THEIR COULTER ACT 5DIFF AL HEMATOLOGY ANALYZER WAS EXPERIENCING HIGH PLATELET COUNTS. IT COULD NOT BE CONFIRMED IF IT WAS CONTROLS OR PATIENT SAMPLES THAT WERE AFFECTED. THE CUSTOMER DID NOT PROVIDE PATIENT OR CONTROL DATA. THERE WAS NO REPORT OF CHANGE OF PATIENT TREATMENT OR AFFECT TO THE PATIENT.
Patient problems: Test Result
MAUDE report 7988190 ↗
FDA clearance and classification
Cleared through 510(k) K992511 on Oct 15, 1999 (decision: Substantially Equivalent). Submitted by Abx Diagnostics as “Abx Pentra 60 Hematology Analyzer”. The FDA review took 80 days. FDA record ↗
The FDA regulates product code GKZ (counter, differential cell) under 21 CFR 864.5220 as a Class II device. 21 CFR 864.5220 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K992511. One submission often covers many models, so check the product and lot details in each record.
- Z-0039-04 · Sep 8, 2003 · TerminatedCoulter AcT 5diff Open Vial Hematology Analyzers Part Numbers: 6605580, 6605581, 6605604
Common questions about the COULTER AcT 5diff
Has the COULTER AcT 5diff been recalled?
No FDA recall record in our data names this exact device identifier (DI 15099590576462), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the COULTER AcT 5diff?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 20, 2018. That report lists device problem “Output Problem” (1); patient problem “Test Result” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the COULTER AcT 5diff?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the COULTER AcT 5diff FDA approved?
It was cleared through 510(k) K992511 on Oct 15, 1999. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the COULTER AcT 5diff, and is it still sold?
The FDA's device database lists Beckman Coulter, Inc. as the company responsible for it (brand COULTER AcT, model 5diff). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Counter, Differential Cell devices
- Cytomics FC500 UPS (CXP)Beckman Coulter, Inc. · Counter, Differential Cell1,196 reports
- CELL-DYN 08H67-01Abbott Laboratories · Counter, differential cell6 recalls269 reports
- Alinity 09P6801Abbott Laboratories · Counter, differential cell2 recalls96 reports
- FACSCanto 338960Becton, Dickinson And Company · Counter, differential cell1 recall117 reports
- Cytomics FC500 UPS (MPL)Beckman Coulter, Inc. · Counter, Differential Cell141 reports
- CELL-DYN 08H00-01Abbott Laboratories · Counter, differential cell1 recall90 reports
- CELL-DYN 09H39-01Abbott Laboratories · Counter, differential cell123 reports
- BD Multitest 662995Becton, Dickinson And Company · Counter, differential cell2 recalls1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.