Skip to content

BITE COMPRESSION SCREWS 1 (REF 001-C-35014)Recalls & reported problems

Orthofix Srl · LOW PROFILE HEADED COMPRESSION SCREW, D 3.5MM X 14MM · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 18056099643191), received between Feb 15, 2018 and Feb 15, 2018 — classified as 1 injury.

The most frequently reported specific device problem is “Mechanical Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Mechanical Problem1

Patient problems

  • Bone Fracture(s)1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 15, 2018Mechanical Problem; Mechanical Problem

    THE INFORMATION PROVIDED BY THE LOCAL DISTRIBUTOR INDICATES: HOSPITAL NAME: (B)(6); SURGEON NAME: DR. (B)(6); DATE OF INITIAL SURGERY: (B)(6) 2018; BODY PART TO WHICH DEVICE WAS APPLIED: NA; SURGERY DESCRIPTION: BUNION SURGERY; PATIENT INFORMATION: NA; PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE; TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. EVENT DESCRIPTION: DURING BUNION SURGERY, SCREWS WOULD NOT ENGAGE WHEN BEING PLACED IN THE PATIENT. THE SIZE 14 DID ENGAGE WHEN USED WITH A 2.5 ARTHREX DRILL BIT. SCREWS KEPT SPINNING NO MATTER HOW MUCH PRESSURE WAS APPLIED. 3 DOCTORS TRIED TO PLACE THE SCREW. PATIENT'S FIRST METATARSAL WAS DAMAGED AND ANTERIOR CORTEX WAS COMPROMISED. THE THREE SCREWS WERE REMOVED AND REPLACED WITH A DIFFERENT PRODUCT. THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT; THE SURGERY WAS NOT COMPLETED WITH THE DEVICE: DR. USED SYNTHESES PLATES AND SCREWS; THE EVENT LED TO A CLINICALLY RELEVANT INCREASE IN THE DURATION OF THE SURGICAL PROCEDURE: 2.5 HRS; AN ADDITIONAL SURGERY WAS NOT REQUIRED; A MEDICAL INTERVENTION (OUTPATIENT CLINIC) WAS NOT REQUIRED; COPIES OF THE OPERATIVE REPORT ARE NOT AVAILABLE; COP

    Patient problems: Bone Fracture(s)

    MAUDE report 7272679 ↗

FDA clearance and classification

Cleared through 510(k) K132893 on Nov 20, 2013 (decision: Substantially Equivalent). Submitted by Icon Orthopaedic Concepts Dba Edge Orthopaedics as “Edge Orthopaedics Bite Compression Screw”. The FDA review took 65 days. FDA record ↗

The FDA regulates product code HWC (screw, fixation, bone) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the BITE COMPRESSION SCREWS 1

Has the BITE COMPRESSION SCREWS 1 been recalled?

No FDA recall record in our data names this exact device identifier (DI 18056099643191), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the BITE COMPRESSION SCREWS 1?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Feb 15, 2018. That report lists device problem “Mechanical Problem” (1); patient problem “Bone Fracture(s)” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the BITE COMPRESSION SCREWS 1?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the BITE COMPRESSION SCREWS 1 FDA approved?

It was cleared through 510(k) K132893 on Nov 20, 2013. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the BITE COMPRESSION SCREWS 1, and is it still sold?

The FDA's device database lists Orthofix Srl as the company responsible for it (brand BITE COMPRESSION SCREWS, model 1). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Screw, Fixation, Bone devices

All Screw, Fixation, Bone devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page