VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM 1 (REF 002-D-20014)Recalls & reported problems

Orthofix Srl · NON-LOCKING SCREW, D 2.0MM X 14MM · Class 2

All models of VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM (140)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
1

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 18056099645645), received between Apr 17, 2018 and Apr 17, 2018 — classified as 2 injuries.

The most frequently reported specific device problem is “Mechanical Problem” (2 reports).

1 FDA recall record name this device's identifier.

14 other recalls cover devices cleared under the same FDA submission (K140876); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Apr 6, 2018Class IITerminated

    Firm is conducting a voluntary recall of the Rival Reduce Fracture Plating System and Rival View Plating System. As the result of a complaint investigation, the locking screws were confirmed to not properly engage the plates during surgery.

    Z-2119-2018 · Root cause: Device Design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Mechanical Problem2

Patient problems

  • No Code Available2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 17, 2018Mechanical Problem; Mechanical Problem

    THE INFORMATION INITIALLY PROVIDED BY THE LOCAL DISTRIBUTOR INDICATES: HOSPITAL NAME: (B)(6); SURGEON NAME: (B)(6); DATE OF SURGERY: (B)(6) 2018; BODY PART TO WHICH DEVICE WAS APPLIED: FOOT; SURGERY DESCRIPTION: FRACTURE TREATMENT; PATIENT INFORMATION: METATARSAL FRACTURE; PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE; TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. EVENT DESCRIPTION: PER REPRESENTATIVE. USING A 4 HOLE REDUCE PLATE TO FIX A 4TH METATARSAL FRACTURE, A 1.5 DRILL BIT WAS USED TO PREPARE ENTRY HOLE FOR THE RIVAL 2.0 SCREW. THE 2.0 SCREWS WERE DIFFICULT TO INSERT AND EVENTUALLY SNAPPED OFF AT THE HEAD. THE REMAINING SCREW WAS NOT REMOVED FROM THE PATIENT. IT WAS PLATED OVER USING A SYNTHES PLATE. A 4 HOLE PLATE WAS ALSO USED ON THE 5TH METATARSAL AND THREE OUT OF THE 4 SCREWS STRIPPED A THE DRIVER SCREW HEAD INTERFACE. THIS IMPLANT WAS EVENTUALLY SEATED AND IS IN PATIENT. THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD ANY ADVERSE EFFECTS ON PATIENT; THE SURGERY WAS NOT COMPLETED WITH THE DEVICE; A REPLACEMENT DEVICE WAS NOT IMMEDIATELY AVAILABLE TO COMPLETE THE SURGERY (PLATED OVER USING A SYNTHES PLATE); THE EVENT LED TO A CLINICALLY REL

    Patient problems: No Code Available

    MAUDE report 7436043 ↗
  • InjuryApr 17, 2018Mechanical Problem; Mechanical Problem

    THE INFORMATION INITIALLY PROVIDED BY THE LOCAL DISTRIBUTOR INDICATES: - HOSPITAL NAME: (B)(6); - SURGEON NAME: (B)(6); - DATE OF SURGERY: (B)(6) 2018; - BODY PART TO WHICH DEVICE WAS APPLIED: FOOT; - SURGERY DESCRIPTION: FRACTURE TREATMENT; - PATIENT INFORMATION: METATARSAL FRACTURE; - PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE; - TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. - EVENT DESCRIPTION: PER REPRESENTATIVE. USING A 4 HOLE REDUCE PLATE TO FIX A 4TH METATARSAL FRACTURE, A 1.5 DRILL BIT WAS USED TO PREPARE ENTRY HOLE FOR THE RIVAL 2.0 SCREW. THE 2.0 SCREWS WERE DIFFICULT TO INSERT AND EVENTUALLY SNAPPED OFF AT THE HEAD. THE REMAINING SCREW WAS NOT REMOVED FROM THE PATIENT. IT WAS PLATED OVER USING A SYNTHES PLATE. A 4 HOLE PLATE WAS ALSO USED ON THE 5TH METATARSAL AND THREE OUT OF THE 4 SCREWS STRIPPED A THE DRIVER SCREW HEAD INTERFACE. THIS IMPLANT WAS EVENTUALLY SEATED AND IS IN PATIENT. THE COMPLAINT REPORT FORM ALSO INDICATES: - THE DEVICE FAILURE HAD ANY ADVERSE EFFECTS ON PATIENT; - THE SURGERY WAS NOT COMPLETED WITH THE DEVICE; - A REPLACEMENT DEVICE WAS NOT IMMEDIATELY AVAILABLE TO COMPLETE THE SURGERY (PLATED OVER USING A SYNTHES PLATE); - THE EVE

    Patient problems: No Code Available

    MAUDE report 7436041 ↗

FDA clearance and classification

Cleared through 510(k) K140876 on Jul 22, 2014 (decision: Substantially Equivalent). Submitted by Icon Orthopedic Concepts, LLC Dba Edge Orthopaedic as “View Plating System,Reduce Fracture Plating System,Bone Screw”. The FDA review took 106 days. FDA record ↗

The FDA regulates product code HWC (screw, fixation, bone) under 21 CFR 888.3040 as a Class II device. 21 CFR 888.3040 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K140876. One submission often covers many models, so check the product and lot details in each record.

  • Z-2122-2018 · Apr 6, 2018 · Terminated
    Locking Screw, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) D 2.7MM X 8MM (002-E-27008), b) D 2.7MM X 10MM (002-E-27010); c) D 2.7MM X 12MM (002-E-27012
  • Z-2131-2018 · Apr 6, 2018 · Terminated
    MTP Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) Small (002-B-01001); b) Medium (002-B-02002); c) Large (002-B-03003)
  • Z-2135-2018 · Apr 6, 2018 · Terminated
    Y-Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) Small (003-C-01001); b) Large (003-C-02001)
  • Z-2129-2018 · Apr 6, 2018 · Terminated
    Lapidus Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size/Step/Left or Right (Part Number): a) Small/0MM Step/Left (002-C-01000L); b) Small/0MM Step/Right (002-C-0100
  • Z-2120-2018 · Apr 6, 2018 · Terminated
    Locking Screw, D 2.0MM X 8MM, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label. Size (Part Number): a) D 2.0MM X 8MM (002-E-20008); b) D 2.0MM X 10MM (002-E-20010); c) D 2.0MM X 1
  • Z-2133-2018 · Apr 6, 2018 · Terminated
    TN Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) Small (002-F-01020); b) Medium (002-F-01025); c) Large (002-F-01030)
  • Z-2134-2018 · Apr 6, 2018 · Terminated
    T-Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) Small (003-B-01001); b) Large (003-B-02001)
  • Z-2127-2018 · Apr 6, 2018 · Terminated
    Evans Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) 6MM Spacer (002-H-00006); b) 8MM Spacer (022-H-00008); c) 10MM Spacer (002-H-00010); d) 12M
  • Z-2132-2018 · Apr 6, 2018 · Terminated
    Straight Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Holes (Part Number): a) 3 Hole (003-D-01001); b) 4 Hole (003-D-02001); c) 6 Hole (003-D-03001)
  • Z-2123-2018 · Apr 6, 2018 · Terminated
    Non-Locking Screw, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a)D 3.2MM X 10MM (002-D-32010) b) D 3.2MM X 12MM (002-D-32012) c) D 3.2MM X 14MM (002-D-320
  • Z-2130-2018 · Apr 6, 2018 · Terminated
    L-Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Left or Right (Part Number): a) Left (003-E-00001L); b) Right (003-E-00001R)
  • Z-2126-2018 · Apr 6, 2018 · Terminated
    CC Plate, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) Small (002-G-01020); b) Medium (002-G-01025); c) Large (002-G-01030)
  • Z-2121-2018 · Apr 6, 2018 · Terminated
    Non-Locking Screw, D 2.7MM X 8MM, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Numbers): a) D 2.7MM X 8MM (002-D-27008); b) D 2.7MM X 10MM (002-D-27010); c) D 2.7
  • Z-2124-2018 · Apr 6, 2018 · Terminated
    Locking Screw, Sterile, Rx Only, ORTHOFIX S.r.r. Italy on label, Size (Part Number): a) D 3.2MM X 10MM (002-E-32010) b) D 3.2MM X 12MM (002-E-32012) c) D 3.2MM X 14MM (002-E-32014)

Common questions about the VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM 1

Has the VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM 1 been recalled?

Yes. 1 FDA recall record names this device's identifier, and the FDA has closed (terminated) it. The recall, Z-2119-2018 (Class II), began on Apr 6, 2018: Firm is conducting a voluntary recall of the Rival Reduce Fracture Plating System and Rival View Plating System. As the result of a complaint investigation, the locking screws were confirmed to not properly engage… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM 1?

The FDA's MAUDE database lists 2 adverse event reports for this device, received on Apr 17, 2018. In those reports, the most common specific device problem is “Mechanical Problem” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM 1?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM 1 FDA approved?

It was cleared through 510(k) K140876 on Jul 22, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM 1, and is it still sold?

The FDA's device database lists Orthofix Srl as the company responsible for it (brand VIEW PLATING SYSTEM, REDUCE FRACTURE PLATING SYSTEM, model 1). Its record shows it as in commercial distribution.