Alexis Contained Extraction System with GelPOINT Mini Advanced Access Platform GTM17Recalls & reported problems
Applied Medical Resources Corporation · Kit Includes: GTB17, ALEXIS CONTAINED EXT SYS 5BX CNGL3, GelPOINT Mini ADV ACCESS PLATFORM · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20607915135700), received between Nov 2, 2017 and Nov 2, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Perforation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Perforation1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 2, 2017Material Perforation; Material Perforation
PROCEDURE PERFORMED -TOTAL LAPAROSCOPIC HYSTERECTOMY BILATERAL SALPINGECTOMY SINGLE OOPHORECTOMY EVENT DESCRIPTION: "[SURGEON] USED THE GTM17 FOR A TOTAL LAPAROSCOPIC HYSTERECTOMY BILATERAL SALPINGECTOMY AND SINGLE OOPHORECTOMY. THE GELPOINT MINI WAS OPENED AT THE START OF THE PROCEDURE. THE XS ALEXIS O WAS INSERTED INTO THE UMBILICUS. THE RING WAS THEN ROLLED INWARDS TO SHORTEN THE SHEATH. THE LARGE TROCAR WAS THEN INSERTED INTO THE CENTRE OF THE GEL CAP. THE CAP WAS THEN PLACED ON THE XS ALEXIS O. THE TOTAL LAPAROSCOPIC HYSTERECTOMY WAS THEN PERFORMED. HALFWAY DURING THE PROCEDURE IT WAS DECIDED THAT A SECOND PORT WAS REQUIRED THROUGH THE GELPOINT MINI. THE CAP WAS REMOVED AND A SECOND PORT WAS INTRODUCED. THE GEL CAP WAS THEN REPLACED AND THE PROCEDURE CONTINUED. AFTER THE COLPOTOMY WAS COMPLETED THE GEL CAP WAS REMOVED AND THE ALEXIS CES BAG WAS FOLDED AND INTRODUCED. THE UTERUS WAS THEN PLACED IN THE BAG AND THE RING OF THE ALEXIS CES WAS PULL THROUGH THE INCISION AND THE SHEATH SHORTENED. THEY THEN ATTEMPTED TO PLACE THE GUARD INTO THE INCISION. AT THIS POINT THEY STRUGGLED TO INSERT THE GUARD INTO THE CENTRE OF THE ALEXIS CES AND INCISION. THEY THEN DECIDED TO UNROLL THE XS
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6997027 ↗
Other Laparoscope, General & Plastic Surgery devices
- HIGH DEFINITION LCD MONITOR OEV262HOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,937 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-12EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,886 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-10EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,086 reports
- Auto Suture OMS-T10BTCovidien LP · Laparoscope, general & plastic surgery1 recall955 reports
- PDB OMS-PDB1000Covidien LP · Laparoscope, general & plastic surgery859 reports
- VISERA 4K UHD CAMERA CONTROL UNIT OLYMPUS OTV-S400Olympus Medical Systems Corp. · Laparoscope, general & plastic surgery777 reports
- Auto Suture OMS-T10SBCovidien LP · Laparoscope, general & plastic surgery1 recall697 reports
- Spacemaker SMBTTRNDXCovidien LP · Laparoscope, general & plastic surgery590 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page