CORE DYNAMICS CD7100GRecalls & reported problems
Conmed Corporation · 10/12MM CORE AUDIBLE DILATING TROCAR · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20653405046001), received between Mar 21, 2016 and Mar 21, 2016.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Detachment Of Device Component1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
Mar 21, 2016Break; Detachment Of Device Component
THE END-USER REPORTED THAT WHILE UTILIZING THE ENTREE II 5X90MM DISPOSABLE TROCAR KIT IN A LAPAROSCOPIC MYOMECTOMY, AND AFTER APPROXIMATELY 1.5 HOURS INTO THE PROCEDURE THE END-USER NOTICED THE 5MM ENTREE II CANNULA VALVE (COMPONENT OF THE TROCAR KIT) WAS DAMAGED AND A SMALL PART OF THE SILICONE VALVE WAS DETACHED FROM THE VALVE AND ALLEGEDLY DROPPED INTO THE PATIENT. THE PART THAT DETACHED FROM THE VALVE WAS REPORTED AS TINY IN SIZE AND TRANSPARENT AND PER THE END-USER WAS NOT REMOVED FROM THE PATIENT LEAVING AN UN-RETRIEVED DEVICE FRAGMENT WITHIN THE PATIENT. THE PROCEDURE WAS COMPLETED WITHOUT FURTHER INCIDENT AND IT WAS REPORTED THAT THERE WAS NO INJURY TO THE PATIENT.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 5513653 ↗
Other Laparoscope, general & plastic surgery devices
- HIGH DEFINITION LCD MONITOR OEV262HOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,937 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-12EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,886 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-10EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,086 reports
- Auto Suture OMS-T10BTCovidien LP · Laparoscope, general & plastic surgery1 recall955 reports
- PDB OMS-PDB1000Covidien LP · Laparoscope, general & plastic surgery859 reports
- VISERA 4K UHD CAMERA CONTROL UNIT OLYMPUS OTV-S400Olympus Medical Systems Corp. · Laparoscope, general & plastic surgery777 reports
- Auto Suture OMS-T10SBCovidien LP · Laparoscope, general & plastic surgery1 recall697 reports
- Spacemaker SMBTTRNDXCovidien LP · Laparoscope, general & plastic surgery590 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.