Skip to content

ELITECROSS Support Catheter MGC39090ARecalls & reported problems

Cordis US Corp. · Support Catheter · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20705032067482), received between May 10, 2022 and May 10, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Crack” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Crack1
  • Difficult to Remove1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 10, 2022Crack; Difficult to Remove; Crack; Difficult to Remove

    AS REPORTED, THE DISTAL END OF THE AN 82CM ANGLED - EXTRA SUPPORT ELITECROSS SUPPORT CATHETER BECAME TRAPPED AT THE POINT OF TOTAL OCCLUSION AND WAS DIFFICULT TO REMOVE. ADDITIONALLY, AFTER REMOVAL OF THE ELITECROSS SUPPORT CATHETER, THERE WAS A CRACK OBSERVED AT THE DISTAL TIP. THE PROCEDURE WAS COMPLETED WITH THE USE OF AN UNKNOWN BALLOON CATHETER AND THE IMPLANTATION OF AN UNKNOWN STENT. THERE WAS NO REPORTED INJURY TO THE PATIENT. THIS WAS DURING A PROCEDURE TO TREAT A SEVERELY CALCIFIED, CHRONIC TOTALLY OCCLUDED (CTO) LESION IN THE MID SUPERFICIAL FEMORAL ARTERY (SFA) IN WHICH A CONTRALATERAL APPROACH WAS MADE WITH THE ELITECROSS SUPPORT CATHETER. THERE WAS NO TORTUOSITY TO THE TARGET VESSEL. THE ELITECROSS SUPPORT CATHETER WAS STORED AND PREPPED PER THE INSTRUCTIONS FOR USE (IFU) WITHOUT DIFFICULTY. THE DEVICE DID NOT KINK DURING THE PROCEDURE AND REMAINED IN ONE PIECE DURING REMOVAL. IT WAS REPORTED THAT A NON-CORDIS GUIDEWIRE WAS ABLE TO CROSS THE LESION, THERE WAS NO DAMAGE TO THE GUIDEWIRE, AND IT WAS ABLE TO BE REMOVED FROM THE PATIENT WITHOUT ANY ISSUES. IT WAS MENTIONED BY THE PHYSICIAN THAT THE USE OF EXCESSIVE FORCE IN THE VICINITY OF SEVERE CALCIFICATION COULD HAVE

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14347739 ↗

FDA clearance and classification

Cleared through 510(k) K150187 on May 19, 2015 (decision: Substantially Equivalent). Submitted by Cordis Corporation, A Johnson & Johnson Company as “ELITECROSS Support Catheter”. The FDA review took 112 days. FDA record ↗

The FDA regulates product code PDU (catheter for crossing total occlusions) under 21 CFR 870.1250 as a Class II device. 21 CFR 870.1250 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the ELITECROSS Support Catheter MGC39090A

Has the ELITECROSS Support Catheter MGC39090A been recalled?

No FDA recall record in our data names this exact device identifier (DI 20705032067482), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the ELITECROSS Support Catheter MGC39090A?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 10, 2022. That report lists device problems “Crack” (1) and “Difficult to Remove” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the ELITECROSS Support Catheter MGC39090A?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the ELITECROSS Support Catheter MGC39090A FDA approved?

It was cleared through 510(k) K150187 on May 19, 2015. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the ELITECROSS Support Catheter MGC39090A, and is it still sold?

The FDA's device database lists Cordis US Corp. as the company responsible for it (brand ELITECROSS Support Catheter, model MGC39090A). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Catheter for crossing total occlusions devices

All Catheter for crossing total occlusions devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page