ELITECROSS Support Catheter MGC39090XRecalls & reported problems

Cordis US Corp. · Support Catheter · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20705032067505), received between Jan 15, 2020 and Jan 15, 2020 — classified as 1 malfunction.

The most frequently reported specific device problem is “Retraction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Retraction Problem1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 15, 2020Retraction Problem; Retraction Problem

    AS REPORTED, THE 82CM ELITECROSS EXTRA SUPPORT WAS INSERTED TO THE PATIENT BUT IT WAS NOT ABLE TO CROSS THE LESION THEREFORE, IT WAS REMOVED AND NOTED THAT IT WAS FRAYED AT THE DISTAL END. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE WAS STORED, HANDLED AND PREPPED PER THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DIFFICULTY EXPERIENCED IN PREPPING THE DEVICE. THERE WAS NO DIFFICULTY REMOVING THE PRODUCT FROM THE PACKAGING. THERE WAS NO VISIBLE DAMAGE NOTED TO THE DEVICE PRIOR TO OPENING THE PACKAGING. THERE WERE NO ANOMALIES NOTED TO THE DEVICE WHEN IT WAS TAKEN OUT OF THE PACKAGING. THE LESION WAS THE ILIAC ARTERY. THE TARGET VESSEL WAS SEVERE CALCIFIED, HAD LITTLE VESSEL TORTUOSITY, 90 PERCENT STENOSIS, HAD A LITTLE ACUTE ANGLE AND A LITTLE BIFURCATING. THE ACCESS SITE WAS THE FEMORAL ARTERY. THEY USED A CONTRALATERAL APPROACH USED. THE ACCESSING TARGET SITE WAS LITTLE CALCIFIED, HAD LITTLE TORTUOSITY, LOW PERCENTAGE OF STENOSIS, HAD A LITTLE ACUTE ANGLE AND A LITTLE BIFURCATING. THERE WAS NO DIFFICULTY TRACKING THROUGH THE VASCULATURE. THERE WAS NO EXCESSIVE FORCE USED DURING INSERTION. THERE WAS A DIFFICULTY THAT REQUIRED THAT ALL CONCOMITANT PRODUCTS BE REMOVED TOGETHER. T

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9591569 ↗

Other Catheter for crossing total occlusions devices

All Catheter for crossing total occlusions devices →