Skip to content

CONMED C2610Recalls & reported problems

Conmed Corporation · CANCELLOUS SCREW, 6.5 X 25 MM · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20845854019389), received between Feb 23, 2026 and Feb 23, 2026 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 23, 2026Adverse Event Without Identified Device or Use Problem

    CONMED JAPAN REPORTED ON BEHALF OF A CUSTOMER THAT THE C2610, CANCELLOUS SCREW, 6.5 X 25 MM DEVICE WAS USED IN AN ACL RECONSTRUCTION SURGERY ON AN UNKNOWN DATE AND IT WAS FOUND POST-OPERATIVELY THAT ¿A PATIENT WHO WAS TREATED USING OUR PRODUCT (CANCELLOUS SCREW 6.5 MM) IN COMBINATION WITH THE SMITH & NEPHEW ENDOBUTTON IS REPORTEDLY EXPERIENCING SOME KIND OF ABNORMALITY IN THE SKIN AROUND THE KNEE WHERE THE IMPLANT WAS PLACED¿. AT PRESENT, IT IS UNCLEAR WHETHER THE OBSERVED CONDITION IS DIRECTLY RELATED TO THE IMPLANTED DEVICES. HOWEVER, THE CURRENT SITUATION SUGGESTS THAT IT WOULD MORE LIKELY BE RELATED TO THE PATIENT¿S INDIVIDUAL SENSITIVITY OR BIOLOGICAL RESPONSE TO THE IMPLANT MATERIAL, RATHER THAN TO A PRODUCT DEFECT.¿. THE PROCEDURE WAS COMPLETED WITHOUT THE USE OF AN ALTERNATE DEVICE, AND WITH NO INTRA-OPERATIVE ISSUES REPORTED. TO DATE, THERE IS NO REPORT OF MEDICAL/SURGICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT. FURTHER INFORMATION WAS REQUESTED BUT WAS NOT MADE AVAILABLE. IT WAS REPORTED THAT DEVICE REMOVAL "IS EXPECTED TO BE CONSIDERED IN THE FUTURE, BUT THE DETAILS ARE UNKNOWN". THIS REPORT IS BEING RAISED DUE TO THE REPORTED INJURY OF AN UNDEFINED SK

    Patient problems: Insufficient Information

    MAUDE report 24414623 ↗

FDA clearance and classification

Cleared through 510(k) K954682 on Feb 9, 1996 (decision: Substantially Equivalent for Some Indications). Submitted by Linvatec Corp. as “Washer, Bolt, Nut, Orthopedic”. The FDA review took 121 days. FDA record ↗

The FDA regulates product code HTN (washer, bolt nut) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the CONMED C2610

Has the CONMED C2610 been recalled?

No FDA recall record in our data names this exact device identifier (DI 20845854019389), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the CONMED C2610?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Feb 23, 2026. Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the CONMED C2610?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the CONMED C2610 FDA approved?

It was cleared through 510(k) K954682 on Feb 9, 1996. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the CONMED C2610 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the CONMED C2610, and is it still sold?

The FDA's device database lists Conmed Corporation as the company responsible for it (brand CONMED, model C2610). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other WASHER, BOLT NUT devices

All WASHER, BOLT NUT devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page