Argo Knotless K4755RSPRecalls & reported problems
Conmed Corporation · 4.75/5.5 mm Argo Knotless Reusable Smooth Punch · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 30653405988353), received between Mar 30, 2023 and Mar 30, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Fragmentation1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 30, 2023Material Fragmentation; Material Fragmentation
THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER AGAINST THE REPORTED DEVICE, K4755RSP, 4.75/5.5 MM ARGO KNOTLESS REUSABLE SMOOTH PUNCH, WAS BEING USED DURING A ROTATOR CUFF REPAIR PROCEDURE ON (B)(6) 2023 WHEN IT WAS REPORTED, ¿I HAD A SURGEON WHO USED THE K4755RSP FOR A ROTATOR CUFF REPAIR. WHEN HE BEGAN TO MALLET THE PUNCH INTO THE BONE A SLIVER OF METAL CAME OFF INSIDE THE JOINT. WHEN WE REMOVED THE PUNCH, IT LOOKED COMPLETELY FINE SO I CAN'T REALLY BE SURE AS TO WHY THIS HAPPENED OTHER THAN MAYBE SOME LEFTOVER MATERIAL WAS ON THE TIP OF THE PUNCH FROM MANUFACTURING?¿. A SERIES OF ASSESSMENT QUESTIONS WERE SENT AND IT WAS REPORTED THE DEVICE DID FRAGMENT BUT IT WAS RETRIEVED WITH THE SHAVER SUCTION. THERE WAS A REPORTED DELAY OF A FEW MINUTES AND ANOTHER PUNCH WAS USED TO COMPLETE THE SURGERY. THERE WAS NO REPORT OF PATIENT OR USER IMPACT, MEDICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16642062 ↗
Other Orthopedic manual surgical instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page