Skip to content

Attest™ 1492VRecalls & reported problems

3m Company · 3M™ Attest™ Super Rapid Readout Biological Indicator for Vacuum-Assisted Steam Sterilizer Cycles 1492V · Class 2

All models of Attest (2)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Aug 22, 2023Class IIOpen, Classified

    Specific lots of 3M Attest Super Rapid Readout Biological Indicators (1492V), 3M Attest Super Rapid 5 Steam-Plus Challenge (41482V, 41482VF), and 3M Attest Super Rapid Readout Steam Challenge (1496V) may contain biological indicators with a cap that melts, deforms and/or cracks following a steam sterilization cycle of 132C and 135C.

    Z-2637-2023 · Root cause: Process control · Recall details · FDA record ↗

FDA clearance and classification

Cleared through 510(k) K121484 on Oct 19, 2012 (decision: Substantially Equivalent). Submitted by 3M Company as “3m Attest(Tm) Super Rapid Readout Biological Indicator, 3m Attest(Tm) Auto-Reader”. The FDA review took 154 days. FDA record ↗

The FDA regulates product code FRC (indicator, biological sterilization process) under 21 CFR 880.2800 as a Class II device. 21 CFR 880.2800 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Attest™ 1492V

Has the Attest™ 1492V been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-2637-2023 (Class II), began on Aug 22, 2023: Specific lots of 3M Attest Super Rapid Readout Biological Indicators (1492V), 3M Attest Super Rapid 5 Steam-Plus Challenge (41482V, 41482VF), and 3M Attest Super Rapid Readout Steam Challenge (1496V) may contain… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

Is the Attest™ 1492V FDA approved?

It was cleared through 510(k) K121484 on Oct 19, 2012. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Attest™ 1492V, and is it still sold?

The FDA's device database lists 3m Company as the company responsible for it (brand Attest™, model 1492V). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Indicator, biological sterilization process devices

All Indicator, biological sterilization process devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page