Conmed Corporation · LOOKING GLASS CAMERA HEAD - 4K 3MOS EYECUP · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 30845854050761), received between May 14, 2024 and May 14, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Unexpected Shutdown” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unexpected Shutdown1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 14, 2024Unexpected Shutdown; Unexpected Shutdown

    THE CUSTOMER REPORTED THAT THE AV41CHE, LOOKING GLASS CAMERA HEAD - 4K 3MOS EYECUP, DEVICE WAS BEING USED DURING A LOBECTOMY PROCEDURE ON 29APR24 WHEN IT WAS REPORTED ¿WE HAD A CAMERA HEAD FAIL IN THE MIDDLE OF A LOBECTOMY AT A VERY COMPROMISING TIME OF THE CASE. THE CAMERA HEAD WAS WORKING FINE UNTIL IT IMAGE SHOOK ON THE SCREEN, THEN VIBRATED OR SHOOK FOLLOWED BY GOING COMPLETELY PINK ON ALL SCREENS. THE SURGEON WAS NEAR AN ARTERY BY THE HEART WHERE HE HAD A BLEEDER AND WAS QUITE UPSET ABOUT IT. THE CAMERA HAD WAS THEN REBOOTED SUCCESSFULLY BY UNPLUGGING AND PLUGGING BACK IN AND WAS USED THE REMAINDER OF THE CASE. THE SURGEON COMMENTED TO ME AFTER THE CASE THAT THIS COULD¿VE BEEN LIFE-THREATENING TO THIS PATIENT. THIS IS QUITE DISTURBING FOR ME AS I WAS IN THE ROOM. HE HAS FILLED AN INCIDENT REPORT WITH THE HOSPITAL, SO I AM DOING THE SAME HERE WITH THIS INCIDENT REPORT. HIS COMMENT TO ME WAS THIS CANNOT HAPPEN DURING THE MIDDLE OF A CASE.¿. THE PROCEDURE WAS COMPLETED WITHOUT THE USE OF AN ALTERNATE DEVICE AND A 5-MINUTE DELAY WAS ALSO REPORTED. THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT OR USER. THIS REPORT IS BEING RAISED O

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19308988 ↗

Other Laparoscope, general & plastic surgery devices

All Laparoscope, general & plastic surgery devices →