Skip to content

MECTRON MT1520+Recalls & reported problems

Mectron SPA · Insert MT1520+ is an osteotomy surgical insert to be used in conjuction with Mectron Piezosurgery hanpieces · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI E322036000210), received between May 18, 2026 and May 18, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information1

Patient problems

  • Nerve Damage1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 18, 2026Insufficient Device Problem Information

    ON FRIDAY MAY 1ST, 2026, MECTRON S.P.A.WAS INFORMED BY THE IMPORTER MECTRON NORTH AMERICA OF AN INCIDENT, WHICH OCCURRED DURING A SURGICAL PROCEDURE AT VIRGINIA MASON MEDICAL CENTER AND THAT MIGHT HAVE INVOLVED ONE OF ITS DEVICE. NO COMPANY PERSONNEL WAS PRESENT AT THE TIME. THE END USER FACILITY REPORTED A CASE OF NERVE AVULSION AND POSSIBLE DUROTOMIES DURING AN UNSPECIFIED PROCEDURE; HANDPIECE OVERHEATING DURING THE SURGERY WAS ALSO REPORTED, THOUGH IT IS UNCLEAR WHETHER OVERHEATING AND THE SURGICAL COMPLICATIONS OCCURRED AT THE SAME TIME. LOTS, SERIALS OF THE INVOLVED DEVICES, PATIENT INFORMATION AND DETAILS ON THE CLINICAL SEQUELAE OF THE ADVERSE EVENT WERE NOT REPORTED, IN SPITE OF REPEATED EFFORTS BY THE IMPORTER TO RETRIEVE SUCH INFORMATION.

    Patient problems: Nerve Damage

    MAUDE report 25198978 ↗

Other Drills, Burrs, Trephines & Accessories (Simple, Powered) devices

All Drills, Burrs, Trephines & Accessories (Simple, Powered) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page