VSI Micro-Introducer Kit 7246VRecalls & reported problems
Vascular Solutions, Inc. · VSI Micro-Introducer Kits are intended for use in percutaneous introduction of up to a 0.018 inch or 0.038 inch guidewire or catheter into the vascular system following a small gauge needle stick. · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M2067246V0), received between Sep 7, 2016 and Sep 7, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Component Falling1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 7, 2016Break; Component Falling
A VSI MICRO-INTRODUCER KIT WAS USED IN A PATIENT PROCEDURE. PATIENT WAS UNDERGOING A PERIPHERAL ANGIOGRAM OF THE RIGHT LOWER EXTREMITY. THE PHYSICIAN OBTAINED LEFT FEMORAL ACCESS WITH A MICRO PUNCTURE SET WITH ULTRASOUND GUIDANCE. UPON RETRIEVAL OF THE MICRO PUNCTURE SET THE HEAD OF THE SHEATH BROKE. THE PHYSICIAN ATTEMPTED TO REMOVE THE REMAINS OF THE SHEATH FROM THE ARTERY, BUT THE SHAFT OF THE SHEATH ALSO BROKE IN HALF LEAVING THE OTHER HALF IN THE FEMORAL ARTERY. INTERVENTIONAL RADIOLOGY WAS CALLED TO ASSIST PER THE PHYSICIAN'S ORDERS. THE PHYSICIANS ATTEMPTED TO RETRIEVE REMAINS OF SHEATH FROM LEFT FEMORAL ARTERY BUT WERE UNSUCCESSFUL. THE PATIENT REMAINED IN STABLE CONDITION WITH NO COMPLAINTS. THE PHYSICIAN ORDERED A CT SCAN AFTER THE PROCEDURE. UPON REVIEWING THE CT RESULTS, THE PATIENT WAS TAKEN TO CSU FOR RECOVERY.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 5932319 ↗
Other Introducer, Catheter devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.