VSI Micro-Introducer Kit 7267VRecalls & reported problems
Vascular Solutions, Inc. · VSI Micro-Introducer Kits are intended for use in percutaneous introduction of up to a 0.018 inch or 0.038 inch guidewire or catheter into the vascular system following a small gauge needle stick. · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M2067267V0), received between Apr 18, 2018 and Apr 18, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment Of Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Detachment Of Device Component1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 18, 2018Detachment Of Device Component; Detachment Of Device Component
RECEIVED SUS VOLUNTARY EVENT REPORT MW5075387 FORM, 21MAR18. MD INSERTED NEEDLE TO GET ACCESS. MD INSERTED GUIDEWIRE. MD INSERTED SHEATH THROUGH GUIDEWIRE. WHEN HE REMOVED INNER SHEATH, HE NOTICED THAT THE INTRODUCER WAS NOT INTACT. HE THEN PULLED BACK THE WIRE AND NOTICED THAT THE REMAINING INTRODUCER WAS STUCK TO THE WIRE. ALL COMPONENTS WERE SUCCESSFULLY RETRIEVED AND ACCOUNTED FOR. DIAGNOSIS OR REASON FOR USE: SICK SINUS SYNDROME.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7441373 ↗
Other Introducer, Catheter devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page