Endoskeleton TCS 5302-3514Recalls & reported problems
Titan Spine, LLC · Interbody Fusion Device 3.5mm Implant Locking Bone Screw 14mm · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M682530235140), received between Jan 28, 2016 and Jan 28, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Detachment Of Device Component1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 28, 2016Break; Detachment Of Device Component
WHILE PERFORMING AN ACDF C4-C7 PROCEDURE TO IMPLANT A TCS 7MM MEDIUM IMPLANT (P/N 5366-1407 LOT# A141204), THE SURGEON HAD A LOCKING COLLAR COME OFF OF ONE SCREW AND THE SCREW HEAD BREAK OFF ANOTHER SCREW. THE SCREW FAILURES OCCURRED WHEN THE SURGEON WAS ADVANCING THE SCREWS WITH A TCS SWIVEL DRIVER. PRIOR TO SEATING THE SCREWS, A TCS CURVED AWL WAS USED TO CREATE THE PILOT HOLES. THE SURGEON WAS ABLE TO SUCCESSFULLY FINISH THE PROCEDURE AT C6/C7 WITH USING DIFFERENT SCREWS. C6/5 WAS AUTO FUSED AND THE SURGEON CHOSE TO USE A DIFFERENT COMPANY IMPLANT AT C4/5. NO HARM CAME TO THE PATIENT DUE TO THE SCREW FAILURES; HOWEVER, SURGERY WAS DELAYED FOR APPROXIMATELY 15 MINUTES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 5397018 ↗
Other Intervertebral fusion device with integrated fixation, cervical devices
- NA 03.617.902Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical103 reports
- NA 03.617.900Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical77 reports
- Divergence® Anterior Cervical Fusion System G6626525Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, cervical75 reports
- Divergence® Anterior Cervical Fusion System G6626526Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, cervical49 reports
- NA 03.617.905Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical29 reports
- NA 03.617.904Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical27 reports
- Divergence® Anterior Cervical Fusion System G6626746Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, cervical21 reports
- NA 03.647.972Synthes GmbH · Intervertebral fusion device with integrated fixation, cervical17 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page