- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI M697T0800100101), received between Jun 10, 2026 and Jun 10, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Improper or Incorrect Procedure or Method1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 10, 2026Improper or Incorrect Procedure or Method
THE MANUFACTURER RECEIVED A COMPLAINT FROM A DISTRIBUTOR ON (B)(6) 2026 REPORTING THAT A 6 MM ANTERIOR KERRISON RONGEUR REPORTEDLY DISENGAGED DURING USE. THE COMPLAINANT INDICATED THE INSTRUMENT WAS BEING USED TO LEVERAGE OPEN THE DISC SPACE, AND DURING ROTATION, THE INSTRUMENT REPORTEDLY DISENGAGED. THE EVENT WAS REPORTED TO HAVE OCCURRED MORE THAN SIX MONTHS PRIOR TO NOTIFICATION; THEREFORE, SPECIFIC DETAILS REGARDING THE TIMING AND CIRCUMSTANCES OF THE EVENT ARE LIMITED. NO PATIENT INJURY, ADVERSE EVENT, OR DELAY IN THE SURGICAL PROCEDURE WAS REPORTED. THE MANUFACTURER ISSUED AN RMA FOR RETURN OF THE COMPLAINT DEVICE; HOWEVER, AS OF (B)(6) 2026, THE DEVICE HAS NOT BEEN RETURNED AND EVALUATION COULD NOT BE PERFORMED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25458035 ↗
FDA clearance and classification
The FDA regulates product code HTX (rongeur) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Irix-A Lumbar Integrated Fusion System T080-0100-10
Has the Irix-A Lumbar Integrated Fusion System T080-0100-10 been recalled?
No FDA recall record in our data names this exact device identifier (DI M697T0800100101), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Irix-A Lumbar Integrated Fusion System T080-0100-10?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jun 10, 2026. That report lists device problem “Improper or Incorrect Procedure or Method” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Irix-A Lumbar Integrated Fusion System T080-0100-10?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Irix-A Lumbar Integrated Fusion System T080-0100-10 FDA approved?
Devices of this type (product code HTX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Xtant Medical Holdings, Inc.
Who makes the Irix-A Lumbar Integrated Fusion System T080-0100-10, and is it still sold?
The FDA's device database lists Xtant Medical Holdings, Inc. as the company responsible for it (brand Irix-A Lumbar Integrated Fusion System, model T080-0100-10). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other RONGEUR devices
- SPOTLIGHT 292904201Depuy Spine, LLC · RONGEUR6 reports
- Symmetry RapidClean® 58-3200J-BDAspen Surgical Products, Inc. · Rongeur5 reports
- SPOTLIGHT 292904202Medos International Sàrl · RONGEUR5 reports
- NA 03.605.001Synthes GmbH · RONGEUR4 reports
- Symmetry Rapidclean® 58-3200-BDAspen Surgical Products, Inc. · Rongeur3 reports
- AESCULAP FF805RAesculap AG · RONGEUR3 reports
- Medicon 57.28.33Medicon eG. Chirurgiemechaniker-Genossenschaft · RONGEUR3 reports
- SPOTLIGHT 292902240Depuy Spine, LLC · RONGEUR3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page